background image

SUBJECT:

  TDV Vending Reliability Checks

MODELS:

  TDV

TOOLS REQUIRED:

  Small flat screwdriver

ESTIMATED TIME:

  <5 minutes

ANY QUESTIONS?  

CONTACT ROYAL VENDORS’ CUSTOMER SERVICE DEPARTMENT

IN NORTH AMERICA, CALL TOLL FREE 1 800 931 9214

F0019077.FRM      

                                                                                        REV.:  A

ISSUE DATE:  23 MAR 2000 

REV. DATE:  23 MAR 2000

045

REASON FOR HELPFUL HINT:

  

Ensuring that all programming is set correctly and the optic sensors are 

properly adjusted is critical to the reliability of the Triple Depth Vender's operation.  This Helpful Hint bulletin explains how to 

ensure these components are adjusted properly.

1.  SPACE-TO-SALES AND SELECTION DEPTH SETTING:

On the TDV, it is of critical importance that space-to-sales and selection depth be programmed in the correct order.

A.  Check or reset the vender's space-to-sales settings.  To change a space-to-sales setting:

i.  Press the service mode button on the vender's control board.

ii.  Press the #1 selection button until the display shows "StoS" or "Space to Sales."

iii.  Press the #3 selection button.  If "CStS" or "Custom Space to Sales" is not shown, press the #1 selection button 

until "CStS" or "Custom Space to Sales" is shown.

iv.  Press the #3 selection button, then press the #1 selection button to reach the selection number to be changed 

(shown as "SL N" or "Selection N," where "N" will be the selection number).  After the selection number, the 

column numbers currently assigned to that selection will be shown ("C1" or "Column 1" for the first column, as 

an example).

v.  Press the #3 selection button, then press the #1 selection button to reach the desired column number to be 

assigned or unassigned.  After the column number, a "0" (unassigned) or "1" (assigned) is shown.

vi.  To change the assignment / unassignment, press the #3 selection button, then press #1.

vii.  Press and hold the #3 selection button for two seconds (model 780-10) or press the #4 selection button (model 

780-12).  

(This is the <exit> function of the vender's programming.)

viii. To scroll to another column to be assigned / unassigned, press the #1 selection button.

ix.  After the desired columns have been assigned or unassigned for the selection number, press <exit>.  The 

display will now show the selection number, followed by the new column assignments.

x.  To scroll to another selection number, press the #1 selection button.

xi.  Once all space-to-sales assignments have been set, press <exit>.  The display will return to "CStS" or "Custom 

Space to Sales."  Press <exit> again to return the display to "StoS" or "Space to Sales."

B. 

After

 space-to-sales, 

always

 reset the selection depth settings.  To reset selection depth:

i.  Press the #1 selection button until the display shows "SdEP" or "Set Selection Depth."

ii.  Press the #3 selection button.  If "ALL" or "All Selections" is not shown, press the #1 selection button until "ALL" 

or "All Selections" is shown.

iii.  Press the #3 selection button.  Then, press the #1 selection button until "2" is shown, 

even if it already said "2" 

when you entered into the depth setting.

iv.  Press <exit>.

If depth is not set after reprogramming or adjusting space-to-sales, selections may double-vend.  Note that 

depth is always set by selection number, not by column number.

2.  OPTIC SENSOR TESTING AND ADJUSTMENT:

The TDV is equipped with two optic sensors, located along the right-hand side below the vend mechanism, that detect 

a product being vended.  These optic sensors are connected to the optic sensor board, a square electronic circuit board 

located near the vender's main controller.  A red indicator LED on the optic sensor board should be lit.  If products are 

double-vending, after space-to-sales and selection depth have been checked for accuracy, test the function of the optic 

sensors.

R

Page:

 1 of 2

Date:

 02 Feb 10

Revision:

 00

Number of 

People 

Required

R

426 Industrial Boulevard • Kearneysville WV  25430-2776 • USA

Telephone:

 +1 304 728 7056 • technicalinquiry@royalvendors.com

Toll-free in North America:

 1 800 931 9214 • 

Fax:

 +1 304 725 4016

Canada:

  +1 905 738 5777 • 

Mexico:

  +52 55 5203 6887

Europe:

  +49 2158 95 1000 • 

Australia:

  +61 2 9890 5433

The  following  areas  of  this  vender  contain  voltage  which 

can  cause  serious  injury  or  even  death:    the  main  power 

cord, supplying 115-230 VAC to the evaporator, EMI filter, 

and refrigeration system; the power line from the EMI filter 

to the ballast and transformer; and the ballast, which can 

produce upwards of 600 volts.  Remove all power from the 

vender before working in any of these areas.

Reviews: