3. Operation with 12V DC supply

A safety fuse must be installed in the power supply between the battery and 
the cooler (for 12V max. 15A).
Before use verify if the voltage of the battery complies with the voltage 
indicated on the rating label on the back of the cooler. If the electrical 
specifications are correct plug the 12V connection cable into the back of the 
cooler and then into the 12V socket/cigarette lighter of your vehicle (Fig. 4).
When the cooler is powered by a car battery, only switch the cooler on while 
the car is running. If the appliance remains switched on when the car is 
stopped, the battery will be discharged and it may be impossible to restart 
the engine.
When operating at 12V the temperature cannot be regulated by the 
thermostat knobs. For switching off the cooler disconnect the 12V  
plug from the socket.

Useful Hints: 

It is recommended to pre-cool the cooler before starting a journey on mains supply and to put only pre-cooled goods inside. 
This guarantees a more efficient cooling performance.

4. Operation with Gas

When connecting the cooler with gas do not use any other energy source at 
the same time (230V mains supply or 12V DC supply).
It is not allowed to connect natural gas or town gas; it is only suitable for 
Butane/Propane gas.
The rating label on the back of the cooler indicates the gas pressure in mbar. 
An appropriate regulator has to be installed between gas bottle and cooler. 
Before connecting the cooler to the gas bottle make sure that the valve of 
the gas bottle is closed. Always use an approved gas hose required by the 
national conditions. The flexible hose connecting the appliance to the gas 
container is to be no longer than 1.5m (regulator and hose are not supplied) 
(Fig. 5). Ensure the position of the hose ensures it is not subject to twisting.  
Should the National conditions require it then the type of connecting hose 
must be changed to ensure compliance with such local regulations.
Only connect the cooler to a gas bottle in well-ventilated areas, away from 
inflammable material. Stay away from heat sources and open flames. Do not 
obstruct the ventilation opening of the container compartment. Precautions 
should be taken to ensure when changing the gas container, that it shall be 
carried out away from a source of ignition.  Precautions shall be taken to 
comply with national regulations relating to the operation of gas appliances 
whilst the vehicle is in motion.
Check the tightness of the connections with soapy water. In the case of soap 
bubbles appearing after opening the valve of the gas bottle, do not operate 
the cooler. Only use the gas bottle standing upright and at least 1 metre away  
from the burner.
Under the small flap on top of the cooler are two knobs. The right knob with  
the marking ‘Press’ and ‘Max’ serves for switching on the unit when operating  
on gas.
This control knob is a combination of ignition and temperature control  
(Fig. 6).

Fig. 4

Fig. 5

Fig. 6

772835 - 3-Way Cooler Instructions.indd   3

21/08/2017   09:06

Summary of Contents for 772835

Page 1: ... according to the rules in force The use in gas mode is prohibited INSIDE tents particularly those with fully sewn in groundsheets In the case of caravans and mobile homes gas should only be used where fumes can be adequately ducted away from the living area The operation in the tent annexe living area is only permitted if it is totally open and very well ventilated The cooler should NEVER be oper...

Page 2: ...t pour put any liquids directly into the cooling compartment but store all food and beverages in closed containers and bottles 2 Operation with 230V AC mains supply Before connection and operation verify that the mains voltage corresponds to the operating voltage of the cooler specified on the ratings label at the back of the appliance If the electrical specifications are correct plug the safety c...

Page 3: ...e installed between gas bottle and cooler Before connecting the cooler to the gas bottle make sure that the valve of the gas bottle is closed Always use an approved gas hose required by the national conditions The flexible hose connecting the appliance to the gas container is to be no longer than 1 5m regulator and hose are not supplied Fig 5 Ensure the position of the hose ensures it is not subje...

Page 4: ...n case the appliance is not in use for a long period of time disconnect from any source of power or gas and leave the lid slightly open in order to let air circulate inside the cooling compartment A handy tip If after such a period the cooler does not cool down switch off again leave it turned upside down Make sure that the connection cables are disconnected After 2 to 3 hours put it upright again...

Page 5: ...tc from the day of purchase under the following conditions If all defects are verifiably attributable to material or production errors and not to improper use the warranty is void if the unit is run with supplementary parts or accessories from other manufacturers The warranty claim is made within the warranty period The purchase receipt must be submitted with the unit Other claims than the above r...

Reviews:

Related manuals for 772835