IMPORTANT NOTE
•
CHECK WITH INSURANCE COMPANY PRIOR TO INSTALLATION. IT IS THE OWNER’S
RESPONSIBILITY TO ENSURE THAT THE APPLIANCE IS ACCEPTABLE TO THEIR INSURANCE
CARRIER.
•
VERIFY LOCAL CODES AND ORDINANCES PRIOR TO INSTALLATION. IT IS THE OWNERS
RESPONSIBILITY TO ENSURE THAT THE APPLIANCE MEETS ALL LOCAL CODES AND ORDINANCES
WHICH TAKE PREEDENCE AND MUST BE OBSERVED PROVIDING THEY ARE MORE RESTRICTIVE.
INSTALLATION MUST BE PERFORMED BY A QUALIFIED INSTALLER
1)
When placing the Solid Fuel INDOOR Boiler, the following should be considered.
a) Review the minimum clearances to combustibles on page 9.
b) Review the recommended stack heights on page 13.
c) Do not locate near any combustible materials, gasoline or other flammable liquids or gases.
d) Check with insurance company and observe local codes and ordinances.
e) The unit requires 115V 15 Amp electrical service for operation.
Failure to keep the solid fuel boiler area clear and free of combustible materials, gasoline or
other
fl ammable liquids or vapors can result in severe personal injury, death or substantial
property damage.
SOLID FUEL APPLIANCES SHALL NOT BE INSTALLED IN A LOCATION WHERE GASOLINE OR OTHER FLAMMABLE
VAPORS ARE LIKELY TO BE PRESENT. The Indoor boil is designed to be installed inside the building being heated
either as a stand alone unit or in combination with another boiler. All installations must be in accordance with local
and state codes which may diff er from this manual.
FOUNDATION
The Indoor boiler must be located on a 2” minimum thickness concrete foundation pad. At a minimum, there must
be a non-combustible pad (concrete, brick, or paver) the width of the appliance extending out 48 inches from the
front of the unit.
Outdoor units should be set on a concrete pad capable of supporting the unit when it is fi lled. A 48” non-combusti-
ble surface is recommend in front of the fuel loading door.
A non-combustible pad must be installed in front of the unit to contain any sparks or coals out of
the loading door or Ash pan door. Fire can result, causing severe personal injury, death or
substantial property damage.
FLOORING
The Solid Fuel Boiler must be placed on a non-combustible fl oor which must extend a minimum
of 6 inches on sides and back. 48 inches are required in front. The unit should never be installed
on carpeting even if a foundation is used. Fire can result causing severe personal injury, death or
substantial property damage.
*** DO NOT INSTALL IN A GARAGE WHERE FLAMMABLES ARE STORED ***
INSTALLATION PLACEMENT
DANGER
DANGER
DANGER