ROZUM ROBOTICS
PULSE DESK
Rev. 5, in effect from Q2 2019
Page
9 | 56
1.2.3
Untwisting mode
The arm can go to the untwisting mode after an emergency shutdown if a
twist
is detected on one
or more motors in its joints during initialization. A
twist
is when a motor has made more than one
360° turn.
Multiple twists can lead to wire breaks and other irreparable damages.
As soon as the arm goes to the untwisting mode, access to the PULSE DESK interface is disabled.
REST API functions causing the robot to move become unavailable.
REST API functions to read parameters remain available even in the untwisting mode.
Simultaneously, a twist detection alert appears on the screen. In the alert, you get the following
information:
which axis (one or more) has a motor with a twist (for axis numbers, see
how many turns to make to untwist the axis (axes)
in which direction to make the turns
If a twist detection alert instructs “Axis 1 — 3 turn clockwise,” this means that you need
to untwist Axis 1 by rotating it 360° three times in the clockwise direction.
Figure 1-3: PULSE arm axes
Summary of Contents for Pulse