background image

28

PX4 AIR

®

LIMITED WARRANTY

RPB

®

 warrants that its Products will be free from defects in materials and workmanship for one (1) 

year, subject to the terms of this limited warranty.  The Products are sold only for commercial use, 
and no consumer warranties apply to the Products. This limited warranty is for the benefit of the 
original Product purchaser, and cannot be transferred or assigned. This is the sole and exclusive 
warranty provided by RPB

®

, and ALL CONDITIONS AND IMPLIED WARRANTIES (INCLUDING 

ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) 
ARE EXCLUDED AND DISCLAIMED FROM WARRANTY COVERAGE.  RPB’s

®

 limited warranty 

coverage does not apply to damage resulting from accident, improper use or misuse of the 
Products, wear and tear resulting from the normal use of the Products, or the failure to properly 
maintain the Products.

RPB’s

®

 limited warranty coverage runs from the original date of purchase of the Products, and 

applies only to warranted defects which first manifest themselves and are reported to RPB

®

 within 

the warranty period.  RPB

®

 retains the right to determine to its reasonable satisfaction whether 

any claimed defect is covered by this limited warranty.

If a warranted defect occurs, RPB

®

 will repair or replace the defective Product (or a component 

of the Product), in its sole discretion.  This “repair or replacement” remedy is the sole and 
exclusive remedy under this limited warranty, and under no circumstances shall RPB’s

®

 liability 

under this limited warranty exceed the original purchase price for the Products (or the applicable 
component). RPB

®

 has no responsibility for incidental or consequential damages, including loss 

of use, maintenance and other costs, and ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES 
ARE EXCLUDED AND DISCLAIMED from this limited warranty.  Contact RPB

®

 to obtain warranty 

service. Proof of purchase must be provided to obtain warranty service.  All costs of returning the 
Products to RPB

®

 for warranty service must be paid by the purchaser.

RPB

®

 reserves the right to improve its Products through changes in design or materials without 

being obligated to purchasers of previously manufactured Products.

LIABILITY

RPB

®

 Safety cannot accept any liability of whatsoever nature arising directly or indirectly from 

the use or misuse of RPB

®

 Safety products, including purposes that the products are not designed 

for. RPB

®

 Safety is not liable for damage, loss or expense resulting from the failure to give advice 

or information or the giving of incorrect advice or information, whether or not due to RPB

®

 

Safety’s negligence or that of its employees, agents or subcontractors.

Summary of Contents for NIOSH PX4 AIR

Page 1: ...uct users Read this manual and the respirator head top Instruction Manual and follow the Product User Safety Instructions page 9 Manuals are regularly updated Make sure this manual is available to all...

Page 2: ...ON AND CLEANING 25 PRODUCT SPECIFICATIONS AND DATA 27 PARTS AND ACCESSORIES 28 WARRANTY AND LIABILITY STATEMENT 30 CONTENTS EXPLANATION OF SIGNAL WORDS AND SYMBOLS The following signal word and safety...

Page 3: ...ctual Property means any patent patented articles patent applications designs industrial designs copyrights software source code database rights moral rights inventions techniques technical data trade...

Page 4: ...lations or recommendations Contaminants or contaminant concentrations are unknown PROTECTION PROVIDED AND LIMITATIONS Improper selection fit use or maintenance of this product can result in injury lif...

Page 5: ...not intrinsically safe AIR SOURCE Powered Air Check that the contaminated area is within the limits of use for a Powered Air Purifying Respirator and determine the type of contamination Once the cont...

Page 6: ...for hoods and or helmets I Contains electrical parts that may cause an ignition in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or dea...

Page 7: ...n should determine what kind of respiratory face and eye head and hearing protection is appropriate for the intended activities and environments of use For example select a respirator appropriate to t...

Page 8: ...e work area Measure and monitor airborne contaminant levels in the work area in accordance with applicable requirements Make sure work area is well ventilated Exposure limits for mixtures The American...

Page 9: ...PX4 AIR PAPR See Respirator Component Diagram page 6 See the instruction manual and approval label for the selected head top for NIOSH approval with the PX4 AIR and the assigned protection factor Use...

Page 10: ...ation and application PAPR Once the contamination level has been confirmed determine the correct filter cartridge to be used for the application to make sure that you are sufficiently protected Make s...

Page 11: ...sure to use the FR Fire Retardant specific model of the PX4 AIR with the FR belt and spark arrestor in place see Respirator Setup and Care page 12 Confined Spaces If this respirator is used in confine...

Page 12: ...well ventilated place where the charger can be monitored and easily observed during charging Battery care Do not use the battery outside the recommended temperature limits 14 F to 131 F 10 C to 55 C...

Page 13: ...ss The triangle warning light will indicate when there is a problem charging When all three lights display green the battery is fully charged FIGURE 2 3 FIGURE 2 4 Fit the battery to the charging stat...

Page 14: ...ce Life of HE Filter Prefilter and Spark Arrestor The HE filter should be replaced if the airflow alarm is activated or the flow indicator reading falls below the 6cfm 170 slpm minimum airflow The HE...

Page 15: ...as you face it rotate the door to the left and latch in place In environments with sparks such as welding or grinding use the 03 982 Spark Arrestor in front of the 03 981 Prefilter This will reduce t...

Page 16: ...oor off the latch 1 2 Remove the 03 985 filter from the Door and dispose of it in a suitable way Install the new replacement 03 985 filter as per Fig 3 3 and 3 4 Inspect the 03 981 Prefilter and repla...

Page 17: ...breathing tube clockwise a turn to lock into position Make sure that it is fully locked in position BREATHING TUBE Select the flexible breathing tube that suits your respirator head top check that th...

Page 18: ...r 04 091 is in the safe range before use so that there is sufficient air flow POWER BUTTON AND BATTERY INDICATION The top row of green lights indicate the charge of the battery 3 lights is fully charg...

Page 19: ...annot be achieved Blocked Speed 1 cannot be achieved Speed 240 slpm The blue lights indicate the selected fan speed The red lights indicate the level of blockage When the lights flash red and blue the...

Page 20: ...a new one LOW BATTERY CHARGE ALARM A pulsing alarm sounds when approximately 10 15 minutes of charge is left in the battery Leave the work area Power the unit off and remove the battery and place on...

Page 21: ...Welding grinding where sparks may be present and High Heat Applications BELT AND SUPPORT ATTACHMENT Take the loose end of the Belt and thread from behind through the outer slot slot furthest out from...

Page 22: ...sure that the battery is securely fitted to the PX4 AIR PAPR 3 BREATHING TUBE Inspect the breathing tube completely looking for splits and cracks in the tube the fittings are held securely in the tub...

Page 23: ...e button after 5 10 seconds indicating that the airflow is below the minimum airflow Remove your hand and the alarm and LED should return to normal operation once the airflow is back to safe levels 7...

Page 24: ...contained RESPIRATOR SETUP AND CARE CONTINUED AIR FLOW Speed 1 Greater than 6cfm 170slpm Speed 2 Greater than 7 4cfm 210slpm Speed 3 Greater than 8 4cfm 240slpm OPERATING TEMPERATURE 14 F to 131 F 10...

Page 25: ...urations Note you should consult with your transport specialist before transporting Lithium ion batteries BATTERY CHARGING 3 hours PRODUCT STORAGE LIFE from new if kept in original sealed packaging A...

Page 26: ...26 PX4 AIR PARTS AND ACCESSORIES FIGURE 9 1 1 3 2 4 5 7 8 9 10 11 10 13 6 14 15 16 17 12...

Page 27: ...C Power Cable AU 2 pin 09 021 AU 16 24 Volt Power Supply with Power Cord 03 952 24 Volt Power Supply with Power Cord AU 03 952 AU 24 Volt Power Supply with Power Cord EU 03 952 EU 24 Volt Power Supply...

Page 28: ...ect occurs RPB will repair or replace the defective Product or a component of the Product in its sole discretion This repair or replacement remedy is the sole and exclusive remedy under this limited w...

Page 29: ...29 NOTES...

Page 30: ...esigned to increase your productivity RPB T LINK Built off the Z Link platform the T Link is designed to work with you not against you Gone are the days of having to fight against a Tyvek respirator T...

Reviews: