Electrical Connection
WARNING
Connection must only be carried out by suitably trained, qualified and skilled
engineers, in accordance with all regional and local electrical codes.
The appliances are electrically rated for a 208/240 V, 60 Hz electrical supply.
The Flexeserve® products are provided with a dedicated power cord and appropriate NEMA Style 6 power
coupler rated for the equipment.
The equipment must be connected to a branch circuit protected grounded supply.
NOTE:
For electrical ratings of the unit, refer to the electrical rating plate located to the rear of
the unit. An example is shown below.
It is highly recommended to provide the equipment with an accessible means of isolation external to the
equipment, i.e. a wall isolator switch.
MODEL
Countertop
3 Zone Unit
4 Zone Unit
5 Zone Unit
Heating
Type/
(WIDTH)
Air Blast
Only
Air Blast/
Combi
Warming
Plate Only
Air Blast/
Combi
Warming
Plate Only
Air Blast/
Combi
Warming
Plate Only
400/560
1500 W
2250 W
725 W
3000 W
950 W
3750 W
1200 W
600
800 W
1050 W
1300 W
770
3000 W
5000 W
950 W
6000 W
1250 W
7500 W
1550 W
1020
1175 W
1600 W
1925 W
WARNING
For all types of installation, ensure the mains lead is in a safe position. Under no
circumstances should any electrical cables or power points be installed directly in contact
with any part of the unit or pose a risk to safety.
If the mains power lead becomes damaged, isolate the equipment and remove from
service immediately until a replacement is fitted.