background image

 

Valid from: 11/2011 

Technical changes reserved 

Page 12 

Doc.:  OM_VIAS & VICD (10D) 

10. 

Dangers 

 

10.1.  Electrical energy 
 
Switch the appliance off immediately upon interruptions in the electrical power supply!  
Any  work  carried  out  on  the  electrical  units  or  utilities  may  only  be  carried  out  in  accordance  with 
electrical  regulations  by  an  electrician  specialist  or  by  those  being  instructed  and  supervised  by  an 
electrician specialist. 
Appliances and unit components which are subject to inspection, maintenance and repair work have 
to  be  completely  disconnected  and  volt-free.    First,  check  as  to  whether  the  activated  parts  have 
indeed been disconnected and are volt-free, then ground and short them out.  Insulate any adjacent 
parts that are also energized! 
 
10.2.  Lift evaporator 
 
Some  models  of  the  refrigerated  display  cases  are  equipped  with  gas  springs,  which  keep  the 
evaporator in the upright position during cleaning and service.  Once the gas springs begin to weaken 
and are not able to keep the evaporator in the upright position anymore, they are to be removed and 
replaced immediately by a specialized service representative.  
 
 
  

11. 

Maintenance  

 

In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the 
goods, the entire technological equipment has to be checked and maintained regularly.  

 

Service and maintenance, troubleshooting  

 

  Prescribed adjustment, service and inspection work is to be completed timely by the manager or if 

necessary by an authorized service technician. 

  The operating personnel are to be informed before the beginning of the maintenance and service 

work. 

  The unit is to be disconnected from the mains before maintaining, inspecting and repairing is 

performed; the main switch is to be guarded against unintended reclosing. 

  Check all screw connections for tight fitting. 

  After finishing maintenance check all safety devices for proper functionality. 

 
 

The following should be done 
 

  complete cleaning of the entire refrigerated well 

  checking the ventilator for functionality 

  checking the thermostat setting  

  checking the temperature of the drop-in refrigerated well 

  checking and cleaning the drainage lines and drip water evaporation 

  checking the gas spring on the evaporator  

  cleaning the condensers on the cooling unit 

  checking the amount of refrigerant  

  making a security check of the unit 

Summary of Contents for VIENNA Air Screen

Page 1: ...Operating and Maintenance instructions Please read this manual carefully before you start to operate your cooling equipment Following the instructions helps to ensure the unit is fully functional at a...

Page 2: ...of the unit 4 5 Safety notes 4 6 Fundamental operating notes 5 6 1 Switching on the appliance 5 6 2 Setting the temperature 5 6 3 Manual defrosting 5 6 4 Lighting 5 7 Operating description 6 7 1 Load...

Page 3: ...a qualified refrigeration technician Air currents near the refrigerating unit resulting from improperly installed ventilation or draughts are to be avoided in order to ensure the efficient functioning...

Page 4: ...can lead to property damages This symbol points to operation tips and especially useful information of optimal use 1 5 Validity These operating instructions are valid for the models VIENNA Closed Disp...

Page 5: ...those intended are to be considered as not being in compliance with the regulations The manufacturer supplier is not liable for any damages resulting from such actions The user bears the entire risk U...

Page 6: ...refrigerated display case is set at a temperature of 39 F Your desired temperature can be set by holding down the SET button 4 and simultaneously pressing UP button 1 for higher temperatures or DOWN b...

Page 7: ...portant to leave adequate free space for the refrigerated air to circulate within the display case Products should be kept clear of the shaded areas shown in the picture A minimum clearance of 1 shoul...

Page 8: ...the bracket in the new position 4 Choose level slant position Display cases with drawer element Models Gastro L and Gastro SL and series Green L and Green SL are equipped with a drawer which offers ea...

Page 9: ...these parts It is absolutely necessary to bear some fundamental things in mind to keep this stainless steel unit working and to maintain its long life always keep the stainless steel surface clean ma...

Page 10: ...rior have to be cleaned with lukewarm soap water Always dry the interior after cleaning After cleaning lift the evaporator remove the lock and drop the evaporator back in its original position Insert...

Page 11: ...2 in and outside ATTENTION Hold glass during opening and cleaning Don t let the glass top fall down Hold the glass and bring it back in end position Front glasses made of insulated double glass Pictur...

Page 12: ...stomer service The ventilators are not running Customer service The air circulation in the well is blocked Clear the ventilation openings Status display and error notification Message Cause Error elim...

Page 13: ...ediately by a specialized service representative 11 Maintenance In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the goods the entire technological...

Page 14: ...11 2011 Technical changes reserved Page 13 Doc OM_VIAS VICD 10D 12 Wiring diagram Wiring diagram VICD and VIAS self contained 115 V 1 PH 60 Hz Wiring diagram VICD and VIAS remote refrigerated 115 V 1...

Page 15: ...Valid from 11 2011 Technical changes reserved Page 14 Doc OM_VIAS VICD 10D Wiring diagram VICD and VIAS self contained 115 208 230 V 1 PH 60 Hz...

Page 16: ...ng diagram VICD and VIAS self contained 115 V 1 PH 60 Hz With rear ventilation Kit including time relay for longer runtime of the fan Wiring diagram VICD and VIAS self contained 115 208 230 V 1 PH 60...

Page 17: ...P a r t s S e r v i c ed i r e c t 1 8 6 6 7 2 7 0 7 2 1 S e r v i c eE ma i l s e r v i c e r p i i n d u s t r i e s c o m P a r t s E ma i l p a r t s r p i i n d u s t r i e s c o m...

Reviews: