 2.  

Purpose of use  

 

The Refrigerated Display Cases have been specially developed for mounting in food and dispensing 
counters.  They are suitable for the refrigeration and presentation of foodstuffs and drinks. 
  

These refrigerated units are not suitable for chilling foods. Any products to be presented have 
to be chilled to the temperature required before being placed in the unit.   

 
Before the Display cases are filled, please wait until the desired temperature has been reached.  
 

 

Do not fill with hot foods and do not overfill! 

 
 

3.  

Proper use the unit 

 
The  drop-in  Refrigerated  Display  Cases  conform  to  current  state-of-the-art  technology,  are 
constructed in accordance with the recognized safety regulations and are reliable. 
However,  health  and/or  life  threatening  circumstances  could  arise  for  the  user  or  a  third  party  or 
damage could be done to the appliance or other property or equipment should the unit be operated by 
non-trained personnel in a manner that is improper or non-conform.   
 
The appliance may only be operated in a technically acceptable condition and in accordance with all 
regulations, safety regulations and conscious of risks with regard to the operating instructions!  Any 
other  uses  beyond  those  intended  are  to  be  considered  as  not  being  in  compliance  with  the 
regulations.  The manufacturer/supplier is not liable for any damages resulting from such actions.  The 
user bears the entire risk.  
Use  in  accordance  with  the  regulations  includes  observance  of  the  mounting  and  operating 
instructions and keeping with the inspection and maintenance regulations. 
After  cleaning  the  appliance  is  to  be  checked  for any  loose  connections and  damages.  Any  defects 
found should be repaired.   
The appliance is not to be used for non-operating purposes. 
Any changes to the appliance are to be made solely by the manufacturer! 
When replenishing the refrigerant only use the refrigerant indicated on the label.  Refilling is only to be 
carried out by authorized service personnel.  
 
 

4.  

Improper use of the unit 

 
The  Refrigerated  Display  Cases  are  not  suitable  for  chilling  foods.    No  foodstuffs  having  a  higher 
temperature  than  indicated  are  to  be  filled  into  the  display.    Safe  operation  at  temperatures  of  less 
than +36°F is not possible. 
 
The ventilation slots in the front and back panels of the display area may not be covered as doing so 
will result in cutting off air circulation and preventing the cooling function.   

 
 

5. 

Safety notes  

 
All  safety  regulations  were  followed  during  manufacturing,  particularly  the  VDE  regulations 
(Association for Electrical, Electronic & Information Technologies) and international CEE regulations. 
The appliance was subject to a comprehensive final check at the plant.  

 

Summary of Contents for VIENNA Air Screen

Page 1: ...Operating and Maintenance instructions Please read this manual carefully before you start to operate your cooling equipment Following the instructions helps to ensure the unit is fully functional at a...

Page 2: ...of the unit 4 5 Safety notes 4 6 Fundamental operating notes 5 6 1 Switching on the appliance 5 6 2 Setting the temperature 5 6 3 Manual defrosting 5 6 4 Lighting 5 7 Operating description 6 7 1 Load...

Page 3: ...a qualified refrigeration technician Air currents near the refrigerating unit resulting from improperly installed ventilation or draughts are to be avoided in order to ensure the efficient functioning...

Page 4: ...can lead to property damages This symbol points to operation tips and especially useful information of optimal use 1 5 Validity These operating instructions are valid for the models VIENNA Closed Disp...

Page 5: ...those intended are to be considered as not being in compliance with the regulations The manufacturer supplier is not liable for any damages resulting from such actions The user bears the entire risk U...

Page 6: ...refrigerated display case is set at a temperature of 39 F Your desired temperature can be set by holding down the SET button 4 and simultaneously pressing UP button 1 for higher temperatures or DOWN b...

Page 7: ...portant to leave adequate free space for the refrigerated air to circulate within the display case Products should be kept clear of the shaded areas shown in the picture A minimum clearance of 1 shoul...

Page 8: ...the bracket in the new position 4 Choose level slant position Display cases with drawer element Models Gastro L and Gastro SL and series Green L and Green SL are equipped with a drawer which offers ea...

Page 9: ...these parts It is absolutely necessary to bear some fundamental things in mind to keep this stainless steel unit working and to maintain its long life always keep the stainless steel surface clean ma...

Page 10: ...rior have to be cleaned with lukewarm soap water Always dry the interior after cleaning After cleaning lift the evaporator remove the lock and drop the evaporator back in its original position Insert...

Page 11: ...2 in and outside ATTENTION Hold glass during opening and cleaning Don t let the glass top fall down Hold the glass and bring it back in end position Front glasses made of insulated double glass Pictur...

Page 12: ...stomer service The ventilators are not running Customer service The air circulation in the well is blocked Clear the ventilation openings Status display and error notification Message Cause Error elim...

Page 13: ...ediately by a specialized service representative 11 Maintenance In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the goods the entire technological...

Page 14: ...11 2011 Technical changes reserved Page 13 Doc OM_VIAS VICD 10D 12 Wiring diagram Wiring diagram VICD and VIAS self contained 115 V 1 PH 60 Hz Wiring diagram VICD and VIAS remote refrigerated 115 V 1...

Page 15: ...Valid from 11 2011 Technical changes reserved Page 14 Doc OM_VIAS VICD 10D Wiring diagram VICD and VIAS self contained 115 208 230 V 1 PH 60 Hz...

Page 16: ...ng diagram VICD and VIAS self contained 115 V 1 PH 60 Hz With rear ventilation Kit including time relay for longer runtime of the fan Wiring diagram VICD and VIAS self contained 115 208 230 V 1 PH 60...

Page 17: ...P a r t s S e r v i c ed i r e c t 1 8 6 6 7 2 7 0 7 2 1 S e r v i c eE ma i l s e r v i c e r p i i n d u s t r i e s c o m P a r t s E ma i l p a r t s r p i i n d u s t r i e s c o m...

Reviews: