11
Decommissioning, disassembly and disposal
11.1 Decommissioning
Personnel:
n
Qualified electrician for high and
medium voltage
Protective equipment:
n
Protective clothing
n
Protective gloves
n
Safety footwear
1.
Have the control room disconnect the power supply to the
TracFeed
®
SFA.
2.
Open the TracFeed
®
SFA enclosure.
3.
Undo the current cables.
DANGER!
Risk of fatal injury due to electric voltage!
4.
If present, disconnect the cables for the signal control.
5.
Determine the position of the mast disconnector and move
the mast disconnector to the desired position with the help of
the crank handle. Observe the mast disconnector and rotate
until the desired position is reached.
ð
The shift linkage is lowered manually.
Fig. 25: Moving the crank handle
Decommissioning, disassembly and disposal
Decommissioning
14.09.2022
TracFeed
®
SFA Electromechanical remote motor drive
63