11
Function
Range
Accuracy
V
0~400.0Vrms
400~600Vrms
±(
1.0%+ 5 digits)
50Hz ~ 500Hz *1
V
0~400.0 V
400~600 V
±(
0.7% + 2 digits)
*1:
For
r
eadings of less than 15% of full
scale (4000 digits), add 4 digits to reading.
The settling time will be longer.
Overload protection:
600 Vrms
Input impedance:
1M
Ω
// less than 100pF.
AC Conversion Type:
AC Conversions are ac-coupled, true rms
responding, calibrated to the rms value of
a sine-wave input. Accuracies are given for
sine-wave at full-scale and non-sine wave
below half-scale. For non sine-wave add
the following Crest Factor corrections:
For Crest Factor of 1.4 to 2.0, add 1.0% to
accuracy.
For Crest Factor of 2.0 to 2.5, add 2.5% to
accuracy.
For Crest Factor of 2.5 to 3.0, add 4.0% to
accuracy.
CF
≦
2 600V//600A
1-3 Electrical Specifications
Accuracy is
±
(% r number of
digits) at 23°C
±
5°C < 80%RH.
Temperature coefficient :
Add 0.2 x (Specified accuracy)
/
°C, < 18°C,
> 28°C
.
Voltage
Summary of Contents for 123-3229
Page 1: ...Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES...
Page 5: ...5 AC V DC V Resistance...
Page 7: ...7 Data Hold 190A 0A Hz ACA 50Hz...
Page 14: ...14...
Page 15: ...Mode d emploi ICM 135R Multim tre pince lectrique FR...
Page 19: ...19 Vc a Vc c R sistance...
Page 21: ...21 Maintien de l affichage 190A 0A Hz ACA 50Hz...
Page 28: ...28...
Page 29: ...Istruzioni d uso ICM 135R Multimetro a pinza que IT...
Page 33: ...33 Vc a Vc c Resistenza...
Page 35: ...35 Memorizzazione dei dati 190A 0A Hz ACA 50Hz...
Page 42: ...42...
Page 43: ...Bedienungsanleitung ICM 135R Strommesszange DE...
Page 47: ...47 AC V DC V Wechsel Gleichspannung Widerstand...
Page 49: ...49 Data Hold Messwertspeicherung 190A 0A Hz ACA 50Hz...
Page 56: ...56...
Page 57: ...57 Instrucciones de uso ICM 135R Mult metro de pinza ES...
Page 61: ...61 V de c a V de c c Resistencia...
Page 63: ...63 Retenci n de datos 190A 0A Hz ACA 50Hz...
Page 70: ...70...
Page 71: ...71...