background image

PM2.5 AIR QUALITY MONITOR / EN 

 

 

10 

05/24/18 Version No. 00

 

MAX MIN: In the MAX/MIN recording mode, current value indication. 

: Battery capacity indication.  

: Low battery indication. 

PM2.5: Fine particulate matter (PM2.5) measurement value indication. 

PM2.5 TWA: Fine particulate matter (PM2.5) measurement TWA value 

indication. 

PM2.5- - - -: DC FAN off indication. 

µ

g/m

3

: PM2.5 measurement unit. 

 : PM2.5 measurement value. 

 : Disable alarm sound indication. 

 : Enable alarm sound indication. 

ALM: Enable the alarm function indication. 

: Measurement value upper to the high limit value or setting the high 

limit value indication. 

:  Measurement  value  below  to  the  low  limit  value  or  setting  the  low 

limit value indication. 

VOCs: volatile organic compounds measurement value indication. 

VOCs TWA: VOCs measurement TWA value indication. 

ppm, mg/m

3 

: VOCs measurement units. 

 : VOCs countdow 600 seconds display. 

: VOCs measurement value. 

: PM2.5 air particle pollution or VOCs air pollution is based on a scale 

from 0 – 9 indication. 

0: Very good, 1: Good, 2 – 4: Moderate, 5 – 8: Poor, 9: Very poor. 

Summary of Contents for 174-9558

Page 1: ...Instruction Manual RS 5322 174 9558 PM2 5 AIR QUALITY MONITOR ...

Page 2: ...5 4 Air Sampling Port 12 6 OPERATING INSTRUCTIONS 13 6 1 Selecting Temperature Unit or 13 6 2 Selecting VOCs unit ppm or mg m 3 13 6 3 Taking Measurements 13 6 4 Setting the TWA Average Time 14 6 5 Setting the Real Time 14 6 6 Taking Maximum MAX and Minimum MIN Recorder Measurements 14 6 7 Taking Alarm Operation 16 6 8 Clearing Memorized data 19 6 9 Manual data Memory and Read Mode 19 6 10 Auto da...

Page 3: ...h any objects into the openings of the meter Do not use any liquid or spray cleaners on the meter Clean only with dry cloth Do not install or operate near any source of heat Do not use the meter in direct sunlight or other bright light source Air sampling port shall not be covered when in use Place the meter in a flat and safe surface to prevent it from dropping Health Disclaimer While the meter c...

Page 4: ...ses of the heart and blood vessels People with lung disease including asthma and COPD Children and teenagers Older adults Research indicates that obesity or diabetes may increase risk New or expectant mothers may want to take precaution to protect the health of their babies Volatile organic compounds VOCs definitions A VOCs is any organic compound having an initial boiling point less than or equal...

Page 5: ...nitor the concentration of PM2 5 VOCs humidity and temperature in the indoor environment The meter convert the concentration of PM2 5 and VOCs in the air into visual data and evaluate the air quality comprehensively Visual and audio alarm will be actived when the air quality reached a critical or alarm limit values 2 1 Features Fine particulate matter PM2 5 measurement Volatile organic compounds V...

Page 6: ... air quality investigations Evaluate effectiveness of air filtration Continuous monitoring of building conditions continuous commissioning Troubleshooting optimization of filtration methods Sales tool for understanding filtration needs 3 SPECIFICATIONS Measurement range PM2 5 0 to 500µg m 3 VOCs 0 to 50ppm Humidity 1 to 99 R H Temperature 20 to 60 4 to 140 Resolution 1µg m3 1ppm 0 1 R H 0 1 0 1 Ac...

Page 7: ...s can be split Alarm Output Open collect output Input impedance 490Ω Maximum applied Voltage 24V DC Maximum drive current 50mA DC Operating temperature and humidity 0 to 60 below 95 R H Storage temperature and humidity 10 to 60 below 70 R H Power supply Four 1 5V LR 6 AA size batteries AC adapter Battery life Approx 5 5 hour LCD backlight ON and DC FAN ON Dimensions 165mm L 93mm W 75mm T 6 5 L 3 7...

Page 8: ...PM2 5 AIR QUALITY MONITOR EN 6 05 24 18 Version No 00 4 PARTS CONTROLS 4 1 Description of Parts Control keys MODE MEM MAX ALM Health Index ...

Page 9: ... Everyone can be affected 55 5 150 4 Purple Very Unhealthy 201 300 Everyone 150 5 250 4 Blue Hazardous 301 500 Everyone 250 5 500 2 LCD display 3 Power and DC FAN control key Press this key to turn on the meter Press this key again to turn on or off the DC FAN When the DC FAN is off the PM2 5 mark is displayed Press this key for 3 seconds to turn off the meter 4 MODE S key MODE key Press this key ...

Page 10: ...d MIN reading c Press this key for 3 seconds to exit this mode and store one set recorded datas to memory 6 MEM key key In the setting mode press this key to move cursor to the desired position MEM key a Memory function Press this key one time to store a measuring data b Clear the stored data Press and hold this key then turn on the meter again There shows rEC CLr no mark on LCD Press key to selec...

Page 11: ...arm signal is available this jack 12 AC adaptor power jack DC 6V 1000mA 13 Battery compartment 4 2 Description of Display ALM MAX MIN SET HOLD Health Index Month Date min sec hour Year SET Setting mode indication HOLD In the user calibration setting mode the measuring data hold indication for calibration MAX In the MAX MIN recording mode maximum value indication MIN In the MAX MIN recording mode m...

Page 12: ...nd indication Enable alarm sound indication ALM Enable the alarm function indication Measurement value upper to the high limit value or setting the high limit value indication Measurement value below to the low limit value or setting the low limit value indication VOCs volatile organic compounds measurement value indication VOCs TWA VOCs measurement TWA value indication ppm mg m3 VOCs measurement ...

Page 13: ... store one sets data into the memory M 39 Manual memory address number indication R Read mode indication R 39 Recall manual memory address number indication Hour 24 PM2 5 or VOCs TWA average time indication or setting Relative humidity measurement value Year Month Date hour min sec Real time or MAX MIN recorded stamp time indication ...

Page 14: ...meter is disigned to operate only with alkaline batteries When the battery voltage drop below the operating voltage the mark will be blink displayed it indicates the batteries need to be changed 5 3 AC Adaptor The AC adaptor allows you to power the meter from a wall outlet When using the AC adaptor the batteries if installed will be by passed The AC adaptor is not a battery charger 5 4 Air Samplin...

Page 15: ...it mark is displayed 4 Press key to select ppm or mg m3 unit now blink on the display 5 Press key to store the desired measure unit 6 3 Taking Measurements 1 Press key to turn on the meter The VOCs need waiting 600 seconds countdown then display the measured values 2 The display will shows the PM2 5 reading PM2 5 µg m 3 VOCs reading ppm or mg m 3 temperature reading or Humidity reading RH PM2 5 or...

Page 16: ...enter the sampling time setting mode the SET TWA St min sec mark is displayed 8 Press key to select the desired sampling time 1 minute 5 minutes or 10 minutes 9 Press key to store the setting value and exit this mode 6 5 Setting the Real Time The meter internal clock is used in the display and for time stamping recorded measurements 1 Press key to turn on the meter 2 Press S key for 3 seconds to e...

Page 17: ...A mark is displayed f MAX PM2 5 reading with its VOCs temperature and humidity reading the PM2 5 mark is blinks g MIN PM2 5 reading with its VOCs temperature and humidity reading the PM2 5 mark is blinks h MAX VOCs reading with its PM2 5 temperature and humidity reading the VOCs mark is blink i MIN VOCs reading with its PM2 5 temperature and humidity reading the VOCs mark is blink j MAX temperatur...

Page 18: ...sured value is not between the setpoints You can also set only one setpoints The figure for illustrative examples of the different measurement based alarm operation modes Hysteresis function is to prevent the alarm operation back and forth when the measured value is near to the setpoint values Hysteresis value should be smaller than difference of the setpoints The following figure for illustrative...

Page 19: ...ter the setting mode the SET mark is displayed c Press S key 9 times to enter the PM2 5 alarm mode select the PM2 5 ALM and no x marks are displayed d Press key to select the desired alarm mode from 1 to 4 then press key to select and to enter the alarm limit values setting mode e The ALM mark indication setting the low limit value the ALM mark indication setting the high limit value and the ALM m...

Page 20: ... complete the humidity limit value setting and exit the alarm limit values setting mode 3 Setting the alarm sound ON OFF a Press key to turn on the meter b Press S key for 3 seconds to enter the setting mode the SET mark is displayed c Press S key 1 times to enter this mode the bEEP and marks are displayed d Press key to select for disable the alarm sound or select for enable the alarm sound e Pre...

Page 21: ... SD card data will be cleared the Sd init and DEL mark are displayed 6 9 Manual data Memory and Read Mode 1 To memorized the reading a Press MEM key each time will store one set of the measured value into the memory At this moment LCD will show the memory address number and the M mark will be disappear one time Total memory size is 39 sets b When the memory is full LCD will show rEC FULL mark 2 To...

Page 22: ...he M mark is disappeared one time one set of reading is stored to the memory g When the memory is filled micro SD CARD 4GB or 99 blocks is full used the Sd FULL mark is displayed h Press MEM key for 3 seconds to exit this mode the recorded block number rEC xx is displayed i The recorded data only download by PC can not recall display by meter 2 Record data with preset start time Perform setting th...

Page 23: ...k displayed j When the start time is reached the A mark is stop flick When the M mark disappeared one time means one set of data has been memorized k When the memory is filled micro SD CARD 4GB or 99 blocks is full used the Sd FULL mark is displayed l Press MEM key for 3 seconds to exit this mode the recorded block number rEC xx is displayed m The recorded data only download by PC can not recall d...

Page 24: ...ayed press or key until the humidity value is same as the standard humidity meter h Press key to enter the PM2 5 second point calibration mode the CA 2 mark is displayed i Wait about 10 minutes until the meter and PM2 5 standard meter reading are stable then press key to hold the meter measured value the HOLD mark is displayed and the PM2 5 2 mark is blink j Press or key until the PM2 5 second poi...

Page 25: ...polarity 4 Affix the battery cover Prevention of Battery Fluid Leakage 1 When the battery power is low replace the new battery in order to avoid the further battery fluid leakage possibility 2 When the meter will not be in use for the long period of time please remove the batteries out of meter to prevent the possibility of battery fluid leakage damage 8 SOFTWARE INSTALLATION AND OPERATION 1 For t...

Page 26: ...AQG European Union United States California Canada Yearly average 35 25 15 10 25 12 12 PM2 5 µg m 3 Daily average 24 hour 75 50 37 5 25 35 30 China Australia Japan South Korea Hong Kong Class1 Class2 Thailand Taiwan Yearly average 8 15 35 15 35 25 15 PM2 5 µg m 3 Daily average 24 hour 25 35 75 35 75 50 35 ...

Reviews: