WARNINGS
Read, understand and follow Safety Rules and Operating Instructions in this manual before
using this meter.
The meter’s safety features may not protect the user if not used in accordance with the
manufacturer’s instructions.
Ensure that the test leads are fully seated in the input jacks and keep fingers away from
the metal probe tips when taking measurements.
Before changing functions using the selector switch, always disconnect the test leads from
the circuit under test.
Use only UL listed test leads with the proper safety category rating.
Comply with all applicable safety codes. Use approved personal protective equipment when
working near live electrical circuits - particularly with regard to arc-flash potential.
Use caution on live circuits. Voltages above 30 V AC rms, 42 V ac peak, or 60 V dc pose a
shock hazard.
Do not use if the meter or test leads appear damaged.
Verify operation before using meter by measuring a known live voltage.
Do not use the meter in wet or damp environments or during electrical storms.
Do not use the meter or near explosive vapors, dust or gasses.
Do not use the meter if it operates incorrectly. Protection may be compromised.
Do not operate meter while Low Battery warning is on. Replace batteries immediately.
Do not apply voltage or current that exceeds the meter’s maximum rated input limits.
Professional True RMS Digital Multimeter/ English
Introduction
The Multimeter wirelessly transmits data to mobile app allowing you to view, save, organize,
share recordings and take measurements from a safe distance. Functions include AC/DC
voltage and current, resistance, continuity, capacitance, frequency, duty cycle, temperature,
diode test and current rang for external flex clamp. True RMS readings provide accurate AC
measurements. This meter is fully tested and calibrated and, with proper use, will provide
many years of reliable service.
Professional True RMS Digital Multimeter/ English
Input Limits
Function
Maximum Input
Voltage AC/DC or AC+DC
1000V AC RMS/1000V DC
µA, mA Current AC/DC 4-20mA%
800mA 1000V fast acting fuse
10A Current AC or DC
3000A Current AC
10A 1000V fast acting fuse
(10A for 30 seconds max. every 15 minutes)
3000A with external sensor
Resistance, Continuity, Diode Test,
Capacitance, Frequency, Duty Cycle
600V AC RMS/600V DC
Temperature
600V AC RMS/600V DC
General Specifications
Insulation
Class 2, Double Insulation
Enclosure
Double Molded, dustproof
Diode Test
Test current 1.5mA typical, open circuit voltage 3V typical
Continuity Test
Audible signal if the resistance is approx. 50Ω or less
Battery Indication
Display
6000 counts OLED display
Over Range Indication
“OL: is displayed
Polarity
Minus symbol “-“ is displayed for negative polarity
Measurement Rate
3 readings per second, nominal
Auto Power Off
After approx. 30 minutes of inactivity
Input Impedance
10MΩ AC/DC Voltage
Data Logger number
(manual/auto)
About 4000 Values
Date and Time Display
TIME DATE setting
AC Response
True RMS
AC Bandwidth
50 to 1000Hz
Battery
A stander AAA 3*1.5V Alkaline battery and Lithium CR1220
battery
Fuses
800mA 1000V (6.3 x 32mm) fast blow/10A 1000V (10 x 38mm)
fast blow