IDM 98IV
&
99IV / EN
19
(6) A Current
Range
Resolution
Accuracy
600.0Ω
0.1Ω
± (0.8% + 5d)
6.000KΩ
0.001KΩ
± (0.8% + 2d)
60.00KΩ
0.01KΩ
600.0KΩ
0.1KΩ
6.000MΩ
0.001MΩ
40.00MΩ*
0.01MΩ
± (1.5% + 5d)
Range
Resolution
Accuracy
600.0Ω
0.1Ω
± (0.8% + 5d)
Range
Resolution
For 98IV
Accuracy
For 99IV
Accuracy
6.000A
DC
0.001A
± (1.0% + 3d)
± (0.8% + 3d)
10.00A
DC
0.01A
± (1.0% + 3d)
± (0.8% + 3d)
6.000A
AC
0.001A
± (1.5% + 3d)
± (1.2% + 3d)
10.00A
AC
0.01A
± (1.5% + 3d)
± (1.2% + 3d)
Maximum measurement Current :
20A
Maximum measurement time :
>5A for max.3 minutes with at least 20 minutes rest time.
>10A for max.30 seconds with at least 10 minutes rest time.
AC Frequency Response :
45 ~ 1kHz (Sine Wave)
Overload Protection :
AC/DC 11A
(7) Peak Hold (For 99
Ⅳ
only) :
Specified accuracy ± 150 digits for < 6000 counts.
Specified accuracy ± 250 digits for >= 6000 counts
(8) Resistance
* There is a little rolling less than ±50 digits when measuring >
10.00 MΩ.
Overload Protection :
AC/DC 1000V
(9) Continuity
Continuity :
Built-in buzzer sounds when the measured
resistance is less than 20Ω and stops when the measured
resistance is more than 200Ω, Between 20Ω to 200Ω the
buzzer may or may not sound.
Continuity Indicator :
2KHz Tone Buzzer
Response Time of Buzzer :
< 500μsec.
Overload Protection :
AC/DC 1000V