OPERATION 

 
This instrument has been designed and tested in accordance with IEC Publication 1010, Safety Require- 
ments for Electronic Measuring Apparatus and has been supplied in a safe condition. This instruction  
manual contains some information and warnings which have to be followed by the user to ensure safe  
operation and to retain the instrument in safe condition. 
 
3-1 Precautions and Preparations for measurement 

 

1. Make sure that the battery is properly connected. 
2. The instrument should only be operated between 0°C

 ~ 

45°C

 

and at less than 75% R.H. 

3. Do not use or store this instrument in a high temperature or high humidity environment and do not store the unit   
    in direct  sunlight. 
4. Do not replace battery with power on condition. 

5. If  the unit  is not to be used for a long period of time, remove the battery. 

6. Do not forget to turn off after use. 

Summary of Contents for ICM33II

Page 1: ...INSTRUCTION MANUAL ICM33II 33RII CLAMP MULTIMETER EN IT DE FR ICM33RII...

Page 2: ...1 ICM 33II 33RII CLAMP MULTIMETER INSTRUCTION MANUAL...

Page 3: ...2...

Page 4: ...r from its packing you should have the following items 1 Digital Clamp meter 2 Carrying case 3 Instruction manual 4 Test lead set one black one red 1 2 Meter Safety Terms as Marked on Equipment ATTENT...

Page 5: ...nel controls and connectors 1 Digital Display The digital display has a 3 1 2 digit LCD readout maximum reading 1999 plus auto polarity decimal point and 2 Input Terminal The black test lead is always...

Page 6: ...mer jaws When the pressure on the lever is released the jaws will close again 6 Transformer Jaws Designed to pick up the AC current flowing through the conductor 7 Hand Guard Designed to protect user...

Page 7: ...6 7 4 2 1 8 3 5 6 9 Figure 1...

Page 8: ...0A range of A function Measuring Rate 4 times per second nominal Low Battery Indication is displayed when the battery voltage drops below the operating voltage 2 2 Environmental Conditions Indoor Use...

Page 9: ...Battery Life Alkaline 200 hours Shock Proof 4 feet drops Maximum Jaw Opening 36mm Maximum Conductor Size 34mm diameter Size 200mm W x 76mm L x 41mm H Weight 360gms including battery Accessories Test...

Page 10: ...igits 40Hz 500Hz 600V r m s 600V 1V AC Conversion Type Average Sensing rms indication 33 AC Conversions are ac coupled true rms responding calibrated to the rms value since wave input the basic accura...

Page 11: ...2 5 reading 5 digits 50 60Hz for 400 600A AC Conversion Type Average Sensing rms indication 33 AC Conversions are ac coupled true rms responding calibrated to the rms value since wave input the basic...

Page 12: ...erate when resistance is less than 50 5 Data Hold Hold display reading for all functions and ranges 6 Auto Power Off Once the Clamp On meter is powered on a timer is activated which will turn the unit...

Page 13: ...d to retain the instrument in safe condition 3 1 Precautions and Preparations for measurement 1 Make sure that the battery is properly connected 2 The instrument should only be operated between 0 C 45...

Page 14: ...uipment and or their employers are reminded that Health and Safety Legislation require them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical...

Page 15: ...is placed around two or more current carrying conductors the meter reading will be FALSE 3 3 AC Voltage Measurement 1 Set the function switch to the V position 2 Connect the black test lead to the CO...

Page 16: ...e the battery 1 Disconnect the test leads from the circuit being measured and turn the meter off Remove the test leads from the front terminals of the meter 2 Position the meter face down 3 Remove the...

Page 17: ...16 Screw Battery Cover 9V Battery Top Case Bottom Case Figure 2...

Page 18: ...h Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com Asia RS Components Pte Ltd 31 Tech Park Crescent Singapore 638040 www rs components com Europ...

Reviews: