IDM-8351 Instruction Manual/English
32
17/11/2016 Version No. 002
1000V
750V
500Vpk
INPUT
FUSE
1.25A/1000V
V
W
SENSE
W
4W
COM
200Vpk
H I
LO
10A
1A
CAT II 600V
Select the Voltage Range
The voltage range can be set automatically or manually.
Auto Range
To turn the automatic range selection On/Off, press the AUTO
key.
Manual Range
Press the Up or the Down key to select the range. The AUTO
indicator turns Off automatically. If the appropriate range is
unknown, select the highest range.
Selectable
Voltage Ranges
Range
Resolution
Full scale
100mV
1μV
119.999mV
1V
10μV
1.19999V
10V
0.1mV
11.9999V
100V
1mV
119.999V