E: The DCI offset causes the input to exceed the lower
dynamic range.
The DC current range should be manually selected when all of
the following conditions are true:
When DCI measurement is used.
When the signals being measured contain both DC and AC
components.
When the amplitude of the AC component in the measured
signal is higher or lower than the dynamic range of the
range being currently selected by the auto-range function.
Maximum DCI
Dynamic Range
Selected DCI Range
Dynamic Range
DC 10mA
± 30mA max
DC 100mA
± 300mA max
DC 1A
± 1.25A max
DC10A
± 12A max