IDM-8351 Instruction Manual/English
42
17/11/2016 Version No. 002
Connection
For 2W measurement, connect the test leads between the V
Ω
terminal and the COM terminal.
For 4W measurement, connect the test leads between the VΩ
terminal and the COM terminal, as you would for 2W
measurement. Connect the sense leads between the LO and
HI sense terminals.
1000V
750V
500Vpk
INPUT
FUSE
1.25A/1000V
V
W
SENSE
W
4W
COM
200Vpk
H I
LO
10A
1A
CAT II 600V
4W only
4W only
4W & 2W
Select the Resistance Range
The resistance range can be set automatically or manually.
Auto Range
To turn the automatic range selection On/Off, press the AUTO
key.
Manual Range
Press the Up or the Down key to select the range. The AUTO
indicator turns Off automatically. If the appropriate range is
unknown, select the highest range.