SAFETY INSTRUCTIONS
17/11/2016 Version No. 002
5
(Note) EN 61010-1:2010 specifies the measurement categories and their
requirements as follows. The IDM-8351 falls under category II 600V.
Measurement category IV is for measurement performed at the source of low-
voltage installation.
Measurement category III is for measurement performed in the building
installation.
Measurement category II is for measurement performed on the circuits directly
connected to the low voltage installation.
Power Supply
WARNING
AC Input voltage: 100/120/220/240 V AC
50/60Hz
The power supply voltage should not fluctuate more than 10%.
Connect the protective grounding conductor of the AC power
cord to an earth ground, to avoid electrical shock.
Fuse
WARNING
Fuse type: 0.125AT 100/120VAC
0.063AT 220/240 VAC
Make sure the correct type of fuse is installed before power up.
To avoid risk of fire, replace the fuse only with the specified
type and rating.
Disconnect the power cord before fuse replacement.
Make sure the cause of a fuse blowout is fixed before fuse
replacement.