IDM-8351 Instruction Manual/English
96
17/11/2016 Version No. 002
Configure Remote Control Interface
USB Interface
The USB device port on the rear panel is used for remote control. The USB port
can be configured as either a TMC or CDC interface.
When configured as a TMC interface, the DMM can be controlled using National
Instruments NI-Visa software*. NI-Visa version 3.0 and above supports USB TMC.
When configured to CDC, the USB port on the DMM will appear as a virtual COM
port to a connected PC. Any terminal program that can communicate via a serial
port can be used for remote control. Before the DMM can be used for remote
control using the CDC or TMC USB class, install the appropriate CDC or TMC USB
driver included on the User Manual CD.
Note
*To use the TMC interface National Instruments Measurement
and Automation Explorer can be used. This program is
available on the NI website, www.ni.com., via a search for the
VISA Run-
time Engine page, or “downloads” at the following
URL, http://www.ni.com/visa/
Configure USB Interface
USB
Configuration
PC connector
Type A, host
DMM connector
Rear panel Type B, slave
Speed
1.1/2.0 (full speed/high speed)