14
15
Function
Range
Resolution
Accuracy ±(% of r digits)
Duty Cycle
20.0% to 80.0% 0 .1%
±(1.2% + 2)
Input Protection: 600V AC RMS or 600V DC
Pulse Width: 0.1 to 100mS
Frequency Range: 5Hz to 10kHz
Sensitivity: >8V RMS
Capacitance
60nF
10pF
±(5.0% + 35)
600nF
100pF
±(3.0% + 5)
6μF
0.001μF
60μF
0.01μF
600μF
0.1μF
6000μF
1μF
±(5.0% + 5)
Input Protection: 600V AC RMS or 600V DC
Temperature
-4 F to 1400°F
0.1°F
±(2.0% + 9°F)
-20°C to 760°C 0.1°C
±(2.0% + 5°C)
Input Protection: 600V AC RMS or 600V DC
True RMS Digital Multimeter/ English
13/12/2017 Version No. 001
Function
Range
Resolution
Accuracy ±(% of r digits)
DC Current
600μA
0.1μA
±(3.0% + 40)
6000μA
1μA
60mA
10μA
600mA
0.1mA
10A
10mA
10A ±(1.5% + 5)
Overload Protection: μA, mA ranges: 800mA/1000V Fuse
10A range: 10A/1000V Fuse
Resistance
600Ω
0.1Ω
±(1.0% + 5)
6kΩ
1Ω
60kΩ
10Ω
600kΩ
100Ω
6MΩ
1kΩ
±(2.0% + 10)
60MΩ
10kΩ
Input Protection: 600V AC RMS or 600V DC
DC Voltage
600mV
0.1mV
±(0.5% + 8)
6V
1mV
±(0.5% + 5)
60V
10mV
600V
0.1V
1000V
1V
±(0.8% + 3)
Input Protection: 1000V AC RMS or 1000V DC
Low Z
DC Voltage
600mV
0.1mV
±(3.0% + 40)
6V
1mV
60V
10mV
600V
0.1V
Input Protection: 600V AC RMS or 600V DC
Input Impedance: Approx. 3kΩ
Frequency
(electrical)
9.999Hz
0.001Hz
±(1.0% + 5)
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999kHz
1Hz
Input Protection: 600V AC RMS or 600V DC
Sensitivity: <8V RMS
True RMS Digital Multimeter/ English
13/12/2017 Version No. 001
Summary of Contents for RS-965T