Heavy Duty True RMS Digital Multimeter/English
Heavy Duty True RMS Digital Multimeter/English
17
13/08/2017 Version No. 001
13/08/2017 Version No. 001
Press SAVE soft key to save Graph. Press
BACK soft key to return.
6-2. Capturing Minimum and Maximum Values
To activate the MAXMIN mode, Press
Software key labled
MINMAX(F4)
, at measure
mode . As shown in Figure, the Meter displays
eat the top of the measurement page, and the
MAXMIN start date and time along the bottom
of the page. In addition, the recorded maximum,
average, and minimum values appear in the
secondary display with their respective elapsed
times.
To stop a MINMAX recording session, press the Softkey labeled Stop. The summary
information in the display freezes, and the softkeys change function to allow saving
the collected data. Pressing the softkey labeled Close exits the MIN MAX record
session without saving the collected data.
To save the MIN MAX screen data, the MIN MAX session must be ended by
pressing the softkey labeled Stop. Next, press the softkey labeled Save.
0.0000 V~
BACK
Auto
range
06:32pm
0
Rate: 0.2 s
Range: 0.01
SAVE
V~
0 .2 6 6 0
Auto
range
08:12pm
STOP
PMAX
MAX MIN
MAX
Average
MIN
0.3493 V~
0.2636 V~
0.2548 V~
6-3. Capturing Peak Values
To activate the peak mode, at AC measure
MINMAX
mode, Press Software key labled
PMAX(F4)
.
6-4. Relative Values
To activate the relative mode, Press the
HOLD/REL
button for greater that 1 second.
6-5. Hold Mode
To freeze the display for any function, press
key HOLD.
Press key save to memory. And press close
return measure.
V~
0 .2 6 7 6
Auto
range
08:12pm
STOP
MAX
PEAK
PMAX
Average
PMIN
0.6354 V~
0.263 V~
-0.5894 V~
V~
-
.0 4 3 0
0
Auto
range
08:20pm
REL
Reference
0.3079 V~
0.2649 V~
GRAPH
MODE
SAVE
MAX
V~
0 .2 8 2 3
Auto
range
06:32pm
SAVE
CLOSE
0
1
2
3
4
5 V
HOLD