Heavy Duty True RMS Digital Multimeter/English

                    This 

1. Introduction

    Professional True RMS Industrial Digital Multimeter and TFT color LCD display, 
providing fast A/D converting sampling time, high accuracy , built-in datalogging 
and Trend Capture feactures. It can trace any interrupted problems of the equipments 

and watch on without person. It is easy to find and solve the problems of the 

production equipments, providing Bluetooth technology and memory the datasheets. 

It is much more safe measurements.
    This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, 

Frequency(electrical & electronic), Duty Cycle, Diode Test, Insulation Test, and 
Continuity plus Thermocouple Temperature. It can store and recall data. It features 
a waterproof, rugged design for heavy duty use. Proper use and care of this meter 

will provide many years of reliable service

2. Safety

WARNING

CAUTION

 

MAX

 

                    This symbol adjacent to another symbol, terminal or operating 
                    device indicates that the operator must refer to an explanation in 

                    the Operating Instructions to avoid personal injury or damage to 
                    the meter.

                    This WARNING 

symbol indicates a potentially hazardous situation, 

                    which if not avoided, could result in death or serious injury.

CAUTION 

symbol indicates a potentially hazardous situation, 

                    which if not avoided, may result damage to the product.

                    This symbol advises the user that the terminal(s) so marked must 
                    not be connected to a circuit point at which the voltage with respect 
                    to earth ground exceeds (in this case) 1000 VAC or VDC.

                    This symbol adjacent to one or more terminals identifies them as 
                    being associated with ranges that may, in normal use, be subjected 
                    to particularly hazardous voltages. For maximum safety, the meter 
                    and its test leads should not be handled when these terminals are 

Summary of Contents for RS-989

Page 1: ...Centre Phase 2 No 618 Yan an Eastern Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Compone...

Page 2: ...e Proper use and care of this meter will provide many years of reliable service 2 Safety WARNING CAUTION MAX This symbol adjacent to another symbol terminal or operating device indicates that the oper...

Page 3: ...quipment Input Protection Limits Function V DC or V AC mA AC DC A AC DC Frequency Resistance Capacitance Duty Cycle Diode Test Continuity Temperature Surge Protection 8kV peak per IEC 61010 Maximum In...

Page 4: ...button for greater that 1 second will return Auto Range HOLD REL Freezes the present reading in the display and allows the display to be saved If Pressing the HOLD REL button for greater that 1 secon...

Page 5: ...nd CONTINUITY measurements Frequency measurements Temperature measurements AC dc amps measurements AC dc milliamps measurements 4 20MA measurements AC dc microampere measurements up to 5 000 uA CAP 4...

Page 6: ...to indicate AC DC on the display 4 Read AC DC measurement value in the display Bluetooth 5 20A for 30 sec MAX every 15 min TEM P C A P 4 2 0 TEM P C F RANGE SETUP SAVE HOLD Auto range 00 00 True RMS M...

Page 7: ...F4 Continuity Check WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Remove the batteries and unplug the l...

Page 8: ...4 Read the temperature in the display Bluetooth 5 20A for 30 sec MAX every 15 min TEM P C A P 4 2 0 TEM P C F RANGE SETUP SAVE HOLD Auto range 00 00 True RMS Multimeter 0078 0 F F1 HOLD REL RANGE F2 F...

Page 9: ...test lead banana plug into the 10A jack 5 Press the MODE button to indicate AC on the display 6 Read the current in the display 5 13 4 20mA MEASUREMENTS 1 Set up and connect as described for DC mA mea...

Page 10: ...collected data Pressing the softkey labeled Close exits the MIN MAX record session without saving the collected data To save the MIN MAX screen data the MIN MAX session must be ended by pressing the...

Page 11: ...F1 V 0 3078 06 02 14 06 32pm PREV 0 1 2 3 4 View Men 06 02 14 06 32pm Rate 0 2 s Range 50M ViewGrap ENTER PREV CL 5V Press the and soft keys to move cursor Press the softkey labeled Then pressing the...

Page 12: ...CLOSE Fno Graph According to graphically display measurement information Fno Mode Releted to the rotary switch function Fno Save Accesses the memory management menu for saving measurement setting up...

Page 13: ...Bluetooth You can use the Bluetooth communication link and transfer the contents of a meter s memory to a PC Open the setup menu Position the menu selector next to the menu item labeled Bluetooth and...

Page 14: ...uare which represents the method of calculation of the voltage or current value Average responding multimeters are calibrated to read correctly only on sine waves and they will read inaccurately on no...

Page 15: ...g time reading will increase 2 C 500 A 5000 A 50mA 500mA 10A 500 A 5000 A 50mA 500mA 10A 20A 30 sec max with reduced accuracy All AC current ranges are specified from 5 of range to 100 of range 5nF 1...

Page 16: ...in 20 to 80 duty cycle and 100kHz 5Vrms min 20 to 80 duty cycle and 100kHz 10 00Hz 10KHz Sensitivity 2Vrms 0 1 to 99 90 Pulse width 100 s 100ms Frequency 5Hz to 150kHz Resolution 0 001Hz 0 01Hz 0 0001...

Reviews: