Surface Installation Instructions
Universal MCB Enclosure
(14 module size)
Stock No. 507-646
1 2 3 4 5 6
7 8 9 10 1112
1. Break out the 'knockouts'
as required, in the top and
bottom panel BUT DO NOT
touch the inner panels as
yet.
3. Knock out the positioning
hole
4. Drive a nail into the wall
and hook on the box.
7. Install the conduits so that
they touch the inner panel.
8. Only then push out the
conduit entry openings in the
inner panel.
5. Adjust the box to a perfect
horizontal position with a
spirit level. Mark off the
fixing hoies. Drill the holes
and insert wall plugs.
6. Secure the box to the wall
with screws. Remove the nail
and put the insulating caps
provided over the fixing
screws.
9. Pull in the wires and
connect the earth and neutral
conductors.
10. Install the ÕdinÕ rail
equipment (ready-mounted)
and make the connections.
11. Finally fix the combined masking frame and door securely
into place, using the four screws provided.
(Note that the door may be fitted to the left or right side.)
2. Knock out the fixing points