Maintenance 

Warning 

To avoid of the risk of electric shock. never connect or disconnect 

plug with wet hands 

                         

 

Cautions 

Turn off the unit and disconnect the power plug before cleaning or 

other routine maintenance. 

Do not remove the float lever from the water tank. 

 

If unit is not used for extended periods of time. 

1.Unplug unit, bundle the power cord, and hang at the back of the unit on the hooks provided 

2.Empty the water tank, wipe dry with cloth and replace in position. 

3.Clean air clean filter. 

4.For storing, stand the unit upright and avoid the exposure to the direct sunlight. 

Important

 

● 

To avoid malfunction or abnormal sound, keep unit upright. 

Body of dehumidifier 

● 

To clean wipe dehumidifier with a dry soft cloth.                 

 

  To remove heavy dirt, use a damp cloth 

 

(Never use a wet cloth for cleaning the controls)

 

To avoid deformation or cracking, do not use thinners   

   or solvent cleaners.

 

Chemical cleaners may cause colour changes to unit. 

_______________________________________________________________________________ 

Water Tank 

● 

Pull out the water tank using indents and take it out.                                                     

● 

Remove the tank cover and wash the inside of the   

tank with water and mild detergent. 

● 

Avoid scratching, do not use abrasives. 

● 

Do not remove the float lever from the tank. 

● 

Wipe off water from the outside of tank with a cloth.   

Replace the cover of the tank and replace..

 

● 

Pass the handle through the hole of the tank cover 

as shown.                                                                                   

Tank cover

 

                                                                                                                   

Hole 

                                                                                                         

Tank Handle     

                                                                                                         

 Float lever 

 

-

14

-

Summary of Contents for DH-320/A

Page 1: ...Dehumidifier Instruction Manual Model DH 320 A...

Page 2: ...Preparation for use 10 Operation 12 Maintenance 14 Continuous drainage 16 Specifications 17 Trouble shooting 17 Please read this instruction manual carefully before operating the dehumidifier This man...

Page 3: ...empt to turn off the dehumidifier by disconnecting the plug Prohibited Never modify the dehumidifier Do not attempt to disassemble or Prohibited service the unit To avoid the risk of the electric shoc...

Page 4: ...ambient temperatures below 0 For indoor use only Prohibited Avoid Exposure to direct sunlight Prohibited Do not spill water on to the dehumidifier Switch off disconnect Prohibited from supply Mop up e...

Page 5: ...d Do not obstruct air vents Do not place object immediately in front of the Prohibited dehumidifier Periodic checking of air filters and water collection or drainage is Schedule regular checkups advis...

Page 6: ...tion This dehumidifier is not suitable for sustained lowering of humidity approx 50 or less This dehumidifier is designed to remove uncomfortable levels humidity in daily life and for enhanced indoor...

Page 7: ...of the dehumidifier The unit should be ideally located taking in to account the spacing s shown Note Since the unit generates heat special care should be taken around the exhaust Note In case of inter...

Page 8: ...nk is filled with water approx 4 0L The timer lamps show the remaining time of operation Press Timer Select switch to set the duration for automatic stopping The indication of current Environment humi...

Page 9: ...e drying of water based spills ____________________________________________________ To dehumidify a small space and inhibit the formation of mould ____________________________________________________...

Page 10: ...e dehumidifier in such a manner that the tank side is easily accessible If used in a confined space try to reduce the amount of air flow allowed in from outside the target area Continuous operation wi...

Page 11: ...Replace the cover securely pressing its perimeter making sure It is flush In case of incorrect alignment of the filter the cover cannot be correctly replaced _________________________________________...

Page 12: ...f the tank 3 Set the tank in the dehumidifier taking care not to damage the level float Note As part of the dehumidifiers operation water is collected in the water tank Once the tank is full the dehum...

Page 13: ...e air outlet flaps for desired operation ___________________________________________________________________________ Press power switch Automatic mode lamp will light up ______________________________...

Page 14: ...the unit is first connected or restarted after a power failure Immediately after a power failure the Automatic mode lamp will flash Press the Power switch to restart the units operation The Efficienc...

Page 15: ...l sound keep unit upright Body of dehumidifier To clean wipe dehumidifier with a dry soft cloth To remove heavy dirt use a damp cloth Never use a wet cloth for cleaning the controls To avoid deformati...

Page 16: ...lease it from the unit Repeat for the other side To dislodge dust from filter use a vacuum cleaner or shake lightly If the filter is heavily fouled Wash in warm water using a neutral detergent Rinse w...

Page 17: ...sure to turn off the dehumidifier and disconnect the power plug Requirements for continuous draining Hose for draining vinyl hose Length Distance to drain approx 30cm Inner diameter 15mm Outer diamet...

Page 18: ...flaps are closed Open one of the flaps 12 Check air filters for blockages Clean the filters as specified or replace 12 Check to see if the air vents are blocked up Remove obstacles from the air vents...

Page 19: ...ay be opened and or closed frequently see the page5 The dehumidifier is used to close to moisture emitting devices some types of heaters Bad smell during operation While the humidity levels are high m...

Reviews: