EN - 10
Temperature Coefficient :
0.27 x Spec. Accy /
C <18
C or >28
C;
(0.15 x Spec.Accy /
F,< 64.4
F or > 82.4
F).
Power Requirements :
Qty. 2 x 1.5V Alkaline type AA batteries.
Fuse (
For 62T only
) :
10mmx38 mm 10Amp 600V ac/dc HBC,
Little fuse KLKD10 or equivalent.
Dimensions (W x H x D) :
74mm x 156mm x 44mm
Accessories :
Battery (installed), Test leads and user manual.
Measurement rate :
Sampling rate 2 times per second nominal.
Altitude :
6561.7 ft (2000m)
Safety :
Complies with EN61010-1:2001, UL61010-1:2001 and
IEC 61010-1:2001.
Weight :
(320g) including battery.
Electrical Specifications
Accuracy is
±
(% r number of digits) at 23°C
±
5°C < 80%RH.
DC / AC Volts
Range
AC Accuracy
200.0mV *
Unspecified
2.000V *
±(
1.5%+5dgt) 50Hz ~ 300Hz
20.00V ~ 200.0V *
±(
1.5%+5dgt) 50Hz ~ 500Hz *
750V AC / 1000V DC
DC Accuracy :
±(0.5% + 2dgt)
Over voltage protection :
1000V DC or 750 V
ACrms.
Input Impedance :
10M
Ω /
/ less than 100pF.
* CMRR / NMRR : (Common Mode Rejection Ratio)
(Normal Mode Rejection Ratio)
V
AC
: CMRR > 60dB at DC, 50Hz / 60Hz
V
DC
: CMRR > 100dB at DC, 50Hz / 60Hz
NMRR > 50dB at DC, 50Hz / 60Hz
AC Conversion Type :
Average sensing rms indication.
AC conversions are ac-coupled
,
true rms responding, calibrated to the
sine wave input.
* The minimum LCD reading is 1400 count in Auto Ranging Mode.
Crest Factor : C.F. = Peak / Rms
+ 1.5% addition error for C.F. from 1.4 to 3