background image

 

 

FO-KDF_2016-08 

 

 

 

FO-KDF 

Delta Fusion Rock Retainer Kit 

 

 

The rock retainer kit allows you to face the fireplace with thin non-supporting facing such as tiles. It is 
not necessary for brick or other self-supporting materials. 

Facing  material  must  be  NON-COMBUSTIBLE  such  as  metal,  brick,  concrete  board  or  ceramic  tile. 
Gypsum board is NOT an acceptable facing material. 

 WARNING: DO NOT RESTRICT AIR FLOW THROUGH THE LOUVERS OF THE FIREPLACE.  

INSTALLATION 

1.  Start by installing the top center mesh assembly of the rock retainer kit. Place the mesh assembly 

on  top  of  the  fireplace  faceplate  so  that  the  arches  match.    Insert  three  of  the  metal  spacers 
provided  between  the  fireplace  faceplate  and  the  rock  retainer  kit  to  achieve  the 

¼”  gap  desired 

along the length of the arch. See Figure 1. 

2.  Center  the  top  assembly  laterally  on  the  facing  of  the  fireplace,  pushing  it  against  the  fireplace. 

Once centered and sitting on the spacers, secure the mesh assembly to the facing of the fireplace 
and  steel  studs  above  by  screwing  directly  into  the  facing  of  the  fireplace  with  the  self-tapping 
screws provided. The screws do not require a pilot hole to pierce the fireplace facing. Remove the 
spacers. 

3.  Place  the  left  side  mesh  assembly  onto  the  fireplace.  Use  the  spacers  along  the  top  and  side  to 

achieve the correct 

¼” spacing. A small gap between the side and center mesh assembly is normal. 

Any gap will not be visible when the stone or tile facing is installed. 

4.  Secure  the  left  side  assembly  with  the  self-tapping  screws  provided 

when  it’s  aligned  to  your 

satisfaction.  

5.  Repeat  steps  3  and  4  for  the  right  side  assembly.  Secure  the  mesh  extending  onto  the  wall  with 

nails or staples to ensure it is solid. 

6.  The 3-sided front wall above the fireplace must be non-combustible. Metal studs are provided with 

the  fireplace,  and  cement  board  is  recommended  for  this  area.  Cement  board  does  not  require 
metal lath or metal mesh to support tile or stone; however adding a layer of metal lath or mesh is 
acceptable if desired. 

7.  Using  a  plasterer's  or  mason  trowel,  apply  a  scratch  coat  of  mortar  that  covers  and  fills  the  wire 

mesh and screen. The mortar must be "thin set", or "thin bed" type. Mix to a firm moist consistency. 
Let the scratch coat set before adding another coat. This will take several hours. Afterwards, apply 
a thinner coat and the facing materials. Do not spread plaster over more than a workable area so 
that the mortar will not set before the facing is applied. If required, use a grout bag to fill the joints. 
Take extra care to avoid smearing on the surface of the facing (see Figure 2). 

 

 