Each  gravity  vent  kit  includes  5’  of  insulated  flexible  ducting,  a  fireplace  adapter,  an  outlet  grill  adapter,  and  a 
decorative outlet grill. 

Additional  5’  lenghts  of  insulated  flexible  ducting  can  be  ordered  with  the  part  code  FO-DUCT5.  Nevertheless, 
gravity vents have a maximum length of 15’. 

Heating Options 

For  increased  air  circulation  and  marginally  more  heat  output,  you  can  add  the  Circulating  Internal  Blower  (FO-
FDHB5-N) to your Louvered fireplace or the Inline Fan (FO-CIF) to your Clean Face fireplace. 

 NOTE

: The FOCUS 320 SBR is equipped with a floor shield to protect the floor under the fireplace. This floor 

shield is made of two parts: the front part is insulated; the back part is a single layered sheet metal. Both parts are 
screwed together and factory installed to cover the entire floor below the firebox. It must never be removed. Only 
when installing the Internal Blower Option can the floor shield be modified. Follow the internal blower installation 
instructions but  before reinstalling  the floor shield, remove the screw, slide the  back part over the front part and 
screw them back together. If you ever remove the internal blower make sure to extend the shield again. 

To maximize the distribution of the heat generated by your fireplace throughout many rooms and different floors, 
consider  the  Central  Heat  Option

4

.  The  Central  Heat  Control  (FO-FDHC6)  will  enable  automatic  control  of  the 

Central Heat Blower via  a  wall thermostat and thermal switch. The Zone  Heat  Control (FO-FDHCZ1) along  with 
Zone Damper Kits (FO-FDHCZ2) will provide the same features as the Central Heat Control but for more than one 
heating zone. If you wish to install the Central Heat Blower on a Clean Face  fireplace,  you will need the Central 
Heat T (FO-T) that will enable you to connect the central heat duct along with the left gravity vent on the fireplace. 

For a simple way to circulate a moderate amount of warm air from the fireplace to another room, we offer the Heat 
Dump  Kit  (FO-HD).  It  includes  a  180  cfm  blower  and  is  most  often  used  to  provide  supplemental  heating  to  a 
basement room when the fireplace is on the main floor, but it can also be used to send the warm air to an adjacent 
room or upstairs. The duct maximum length is 8' for the FO-HD.  

General Options 

To simplify the installation of thin non-combustible materials such as ceramic tile or sliced brick, we have designed 
a rock retainer kit. It is not designed or required for full brick or stone. With a Louvered fireplace, you can choose to 
leave all the black metal completely exposed or completely covered with non-combustible material. Whether you 
have chosen a Louvered or Clean Face fireplace, the FO-KN kit will help you finish the facing of the fireplace as 
you wish. Thin materials can also be installed directly on the face of the fireplace using high temperature silicone 
as glue, without a rock retainer kit. 

Decorative andirons (FO-A) are also an optional feature.  The decorative andirons are made of cast iron and are 
more  aesthetically  appealing  than  the  basic  ones  included  with  the  fireplace.   The  decorative  andirons  are  also 
taller, which reduces the chance of logs rolling forward. 

 NOTE

: Many options require wiring and/or electricity for their installation. If there is any chance that any of these 

options will be installed in the future then suitable wiring should be run during framing. Otherwise, it will be difficult 
to install these options later. You can refer to page 25 for a list of options that require electricity. 

Detailed  installation  instructions  are  included  in  the  box  with  each  option. These  can  also  be  obtained  from  our 
Internet Web Site: www.icc-rsf.com.  

WARNING: THIS FIREPLACE HAS NOT BEEN TESTED WITH A GAS LOG SET (UNVENTED OR VENTED). 

TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL A GAS LOG SET (UNVENTED OR VENTED) INTO 
THIS  FIREPLACE.  DO  NOT  INSTALL  A  GAS  LOG  LIGHTER  BECAUSE  THE  HEAT  PRODUCED  BY  THE 
FIREPLACE WILL PERMANENTLY DAMAGE THE GAS LOG LIGHTER. 

 

4

 

Not allowed in a mobile home installation.

 

Summary of Contents for FOCUS 320 SBR

Page 1: ... Residential Factory Built Fireplace Operation Maintenance Installation FOCUS 320 SBR Keep these instructions for future use Industrial Chimney Company Inc 400 J F Kennedy St Jerome QC Canada J7Y 4B7 Telephone 450 565 6336 www icc rsf com ...

Page 2: ...L 3 GENERAL SPECIFICATIONS 4 THE COMBUSTION CONTROL SYSTEM 4 OPTIONS 4 UNIT DIMENSIONS AND CLEARANCES 6 OPERATION 8 AIR CONTROLS 8 IMPROVING EFFICIENCY 8 IMPORTANCE OF DRAFT 8 BURN TIME VS HEAT OUTPUT 8 FUEL 9 FIRST FIRES 9 LIGHTING 9 REFUELING 9 TROUBLESHOOTING PROBLEMS 10 MAINTENANCE 10 CHIMNEY CLEANING 10 DISPOSAL OF ASHES 11 GENERAL CLEANING 11 GLASS CLEANING 11 PAINT 11 DOOR ADJUSTMENT 11 LOU...

Page 3: ... not specified for use with this fireplace 11 The burn rate is set by the automatic air control at the factory DO NOT tamper with the air control DO NOT install a flue damper that would allow you to reduce the chimney draft and thus slow the minimum burn rate 12 To avoid damaging the fireplace DO NOT operate it in a manner inconsistent with the operating instructions in this manual NOTE We strongl...

Page 4: ...r control Control the fire as you would any normal fireplace using one or two logs at a time for a smaller fire or more logs for more heat Remember when the fireplace is hot the automatic air control will reduce the combustion air inlet since the bi metallic coil will shut the air control damper part way OPTIONS Louver Options There are different ways you can finish your fireplace1 You can choose ...

Page 5: ...o circulate a moderate amount of warm air from the fireplace to another room we offer the Heat Dump Kit FO HD It includes a 180 cfm blower and is most often used to provide supplemental heating to a basement room when the fireplace is on the main floor but it can also be used to send the warm air to an adjacent room or upstairs The duct maximum length is 8 for the FO HD General Options To simplify...

Page 6: ...4 5 18 1 2 efer to able 1 for minimum depth of hearth extension efer to able 1 for minimum width of hearth extension on combustible hearth extension and spark guard refer to able1 and text for particulars efer to able 1 for maximum mantel shelf depth efer to able 1 for minimum mantel shelf height above the door opening efer to able 1 for minimum distance of side wall to the firebox opening ...

Page 7: ...antel shelf depth see Table 2 for other mantel sizes 12 305 mm K Minimum height of a combustible mantel shelf above the top of the firebox opening to the bottom of the combustible mantel refer to the Installation Mantel section for particulars See Table 2 Table 2 Various Mantel Shelf Depths and Corresponding Installation Heights Maximum Mantel Shelf Depth Minimum Installation Height 0 to 6 20 12 2...

Page 8: ...t from the main floor to the basement This allows you to efficiently heat your primary space while also heating the basement as a secondary space The efficiency will also be influenced by the draft in the chimney which will be influenced by various factors refer to Importance of draft below and by the amount of wood burning at any point see Burn Time vs Heat Output below The efficiency will also b...

Page 9: ...or Open the doors and windows to allow the room to properly ventilate LIGHTING Start by laying your fire starter and kindling Traditional fire starter is crumpled newspaper make sure to use enough to light the kindling 5 6 pieces should do Next lay 3 or 4 layers of kindling crisscrossed over the newspaper Using plenty of kindling ensures that the chimney will heat up quickly and establish a strong...

Page 10: ...unning particularly a kitchen range hood or bathroom exhaust fan This can affect the pressure in the home Try opening a window near the fireplace a little this will equalize the pressure in the home and should correct a draft problem Once proper draft is established the window can be closed Make sure you ve used enough kindling to establish a hot fire quickly The most likely time that smoke will e...

Page 11: ... dealers Follow the directions outlined on the spray can DO NOT attempt to paint the fireplace while it is still warm Keep the spray can away from any source of heat or open flame Ensure that there is adequate ventilation in the room from the time you start painting until the paint is dry Stove Bright is available in a wide range of colors if you want to change the color of your fireplace We recom...

Page 12: ...g with clearances are shown in Figure 1 and Table 1 WARNING IF THIS FIREPLACE IS NOT PROPERLY INSTALLED A HOUSE FIRE CAN RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION INSTRUCTIONS AND CLEARANCES DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS 1 Note the location of roof and floor joists Try to choose a location that does not require cutting them 2 If possible run the chimney up...

Page 13: ...ireplace facing grayed area refer to text for particulars Cold air trap optional Rain Cap Storm Collar Flashing Radiation Shield with a Storm Collar in the Attic Ceiling Radiation Shield Hearth Extension and Beneath Hearth Extension refer to text for particulars Electrical Knock outs on both sides of the fireplace Outside Air Inlet refer to text for particulars Flashing And Roof Radiation Shield ...

Page 14: ...terial over the fireplace facing grayed area refer to text for particulars Cold air trap optional Obstruction plates part of Clean Facing Option FO F2 Rain Cap Storm Collar Flashing Radiation Shield with a Storm Collar in the Attic Ceiling Radiation Shield Hearth Extension and Beneath Hearth Extension refer to text for particulars Electrical Knock outs on both sides of the fireplace Outside Air In...

Page 15: ... and the chimney MUST always be respected A radiation shield must be installed as usual at each floor where the chimney passes through The ICC part is long enough to extend to the outermost plane of the roof which it must also protect CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR WALLS AND CEILING ROOF MUST BE MAINTAINED CEILING CLEARANCE Ceiling clearance is the distance from th...

Page 16: ...e provided with the fireplace 1 Find a convenient location for the insulated flexible duct and outside air inlet The outside air inlet can be above or below floor level see Figure 6 2 Make a 4 5 if using a 5 diameter duct hole in the outside wall of the house Push the outside air inlet in from the outside Seal the joint between the air inlet and the outside wall with an appropriate sealant 3 Place...

Page 17: ...6 17 18 6 20 24 21 26 6 9001 10000 16 6 17 6 19 20 6 24 6 22 27 Flue height is measured from the top of the fireplace to the top of the chimney before installing the rain cap If you have two different offsets two pairs of different elbows simply use the column for two offsets of the biggest pair of elbows at your elevation to get your Minimum Flue Height CHIMNEY INSTALLATION Make sure to read the ...

Page 18: ...e sealer DO NOT use roofing tar 8 Fit the rain cap on the chimney Secure it tightly in place OFFSET CHIMNEY An elbow may be installed directly on top of the fireplace if required See the detailed offset charts in the EXCEL chimney installation manual Use the offset option if you need to clear a joist or pass around a cupboard See Figure 8 and Figure 9 for examples Maximum offset angle In USA 30 In...

Page 19: ...RE If the chimney runs up the outside of the house we recommend that it be enclosed in a chase structure The chase should be constructed in such a way that it is an extension of the home see Figure 10 It should be well insulated between the footings and the floor of the home to prevent heat loss If the climate in your area is mild insulate the chase at least to the first firestop If the climate in...

Page 20: ...st part of the EXCEL chimney where it enters the masonry chimney must be a minimum of 12 from the ceiling NOTE If the ceiling is high enough you can install one or more EXCEL chimney lengths directly on the fireplace before the elbow If you use a flexible liner make sure to be careful when cleaning to ensure that the stainless steel flexible liner is not dislodged in any way Using an Existing Maso...

Page 21: ...end that you position your fireplace install the EXCEL chimney on it and connect to the first length of liner before building the chimney as explained above and shown in Figure 11 The liner sections can easily be installed as the layers of brick are being placed Since this is a new chimney we recommend that you build it to the right size so you do not have to ovalize the liner Remember The stainle...

Page 22: ...minimum width specified in Table 1 I If you are preparing a raised installation you will need a custom made spark guard either a Z shaped spark guard or a right angle spark guard see Figure 13 The Z shaped spark guard must be used if the height between the bottom of the fireplace and the top of the non combustible flooring of the hearth extension is less than or equal to 2 The height of the Z shap...

Page 23: ...erials Each is required for proper operation of the fireplace If the baffle needs to be replaced proceed with care The following steps are to install a new baffle 1 First the refractory bricks should be removed from the firebox as well as the front secondary air tube at the top front of the firebox by removing the cutter pin located on the left side of the front tube 2 Then gently slide the rigid ...

Page 24: ...OCUS 320 SBR Owner s Manual 24 RSF Woodburning Fireplaces LISTING LABEL The listing label is glued to the bottom of the fireplace Just remove the bottom louver the listing label is below the floor shield ...

Page 25: ...FOCUS 320 SBR Owner s Manual 25 RSF Woodburning Fireplaces COMPLETE OPTIONS LIST ...

Page 26: ...FOCUS 320 SBR Owner s Manual 26 RSF Woodburning Fireplaces ...

Page 27: ...r Central Heat FO FDHB6 1 Heat Dump Kit FO HD Rock Retainer Kit FO KN Central Heat T Option FO T Blower internal fan FO FDHB5 N Louvered FOCUS 320 SBR Required Optional Not available Blower internal fan FO FDHB5 N Blower Central Heat FO FDHB6 1 Heat Dump Kit FO HD Rock Retainer Kit FO KN Central Heat T Option FO T Gravity Vent Kit FO V2 1 or 2 or FO V3 1 or 2 Inline Fan FO CIF Possible add ons FO ...

Page 28: ...8 RSF Woodburning Fireplaces REPLACEMENT PARTS Use only genuine RSF parts The use of any substitutes will void the warranty and may put your safety at risk Will be available soon Please contact your RSF dealer if you need assitance ...

Page 29: ...cracked refractory components Repairs or replacements necessitated by vandalism neglect abuse over firing improper fuel or fuel loads or failure to adequately service the unit as stated in the owner s manual Repairs or replacements particularly charges for travel and labor not authorized by RSF Woodburning Fireplaces in advance LIMITATIONS All items found to be defective will be replaced or repair...

Reviews: