If the chimney is enclosed once outside of the house, do not install the outside plate of the angled wall insulated
radiation shield.
Refer to the angled wall insulated radiation shield installation sheets for more detailed installations instructions.
When the chimney passes through a non-combustible exterior wall (e.g. concrete), the angled wall radiation shield
is not required. An opening slightly larger than the chimney can be created through the non-combustible wall. Any
gaps between the chimney and wall can be filled with rock wool insulation and then sealed with silicone.
*Refer to text to determine the appropriate flashing
Figure 13 Offset Chimney Installation Example Figure 14 Offset Chimney Through a Wall Example
Radiation
Shield
Use Offset
Support or
Roof Support
RSF
Fir
epl
ac
e
Radiation
Shield
3 Metal Screws
in Each Joint
Rise
Offset