PEARL 3600 Owner's Manual
20
RSF Woodburning Fireplaces
REFRACTORY BRICK INSTALLATION
Before lighting your first fire, you must make sure the refractory bricks are properly installed inside the firebox. To
remove any of the refractory bricks, just follow the installation procedure in the reverse sequence. Refer to Figure
18 to identify which refractory brick is the left and which is the right at each step of the installation.
1. Start by placing the rear refractory brick in the firebox (1), then the right and left side (2, 3) refractory bricks.
2. Continue by installing the soft insulation (4) on the bottom of the firebox. It fits tight between the front and the
back refractory brick and between both side refractory bricks.
3. Then install the bottom refractory brick (5).
4. Finally, install the two front refractory bricks (6, 7).
These refractory bricks have been designed specifically for the PEARL3600 and no modifications are required to
ensure a proper fit.
Figure 18 Refractory Bricks Installation