PEARL 3600 Owner's Manual
8
RSF Woodburning Fireplaces
LOCATION
We recommend that you take the time to plan your entire installation (fireplace, chimney, and options) before
beginning the actual installation (refer to Figure 3). Your PEARL3600 fireplace may be installed in many different
ways (see Figure 4) without any special floor reinforcement.
Dimensions of the fireplace along with clearances are shown in Figure 1 and Table 1.
WARNING:
If this fireplace is not properly installed, a house fire can result. For your safety, follow the installation
instructions and clearances. Do not pack required air space with insulation or other materials.
1. Note the location of roof and floor joists. Try to choose a location that does not require cutting them.
2. Do not build recessed shelves or cupboards in the enclosure above the fireplace. This must be kept as air
space.
3. If at all possible, run the chimney up through the inside of the house. If it must be run outside, it should be
enclosed in an insulated enclosure (see Installation: Chase Enclosure). Remember, a cold chimney causes
poor draft.
FRAMING
Walls on all interior sides of the fireplace enclosure should be finished and flat. Insulation or other materials should
not be placed in required clearance spaces around the fireplace. Because of the high heat output potential of the
PEARL3600, combustible materials must NOT go closer to the fireplace than the standoffs, top, back and sides.
The framing dimensions are larger
than required for ease of installation.
The Heat Dump Option will require at
least12" additional space on the
selected side. Ensure adequate
space is planned.
Figure 4 PEARL3600 Framing Examples
24 1/2"
12"
38 1/2"
72"
24 1
/2
"
38 1/2"