www.rslogger.com
FTDI Virtual COM Port (VCP) module loaded and it’s advanced settings.
In case the OS would not load the drivers automatically, please choose the “update driver” option manually or v isit the
http://www.ftdichip.com/
page for actual driver updates and installation support for your operating system.
Advanced configuration options with CONFIG.INI file
INI Section
Parameter
Example
Value (default)
Description
[SYSINFO]
FW_VER
1.1.51
Firmware version. Read only
HW_VER
1.1
Hardware version. Read only.
MEMCLEAR
TRUE
Erases the internal memory upon next power up or
USB Flash Mass storage connection.
[FILE]
PASSWORD
RSLOGGER123 USB Flash drive password label. Blank by default.
TIMESTAMP
0
0-disable, 1- Enabled for every byte, 2- Enabled for
active channel switch only
CHANNELMODE
1
1 - one common file for both A and B channels
2 - two separated files for A and B channels
DATAFORMAT
0
0 - ASCII / binary
1 – HEX
[DATETIME]
SETDATE
;SETDATE =
2018-01-01
Date setting. Applicable upon next restart or USB Flash
drive connection (with config.ini). Last set time would
be stored as a comment “;” in config.txt file.
SETTIME
;SETTIME =
12:00:00PM
Time setting. Applicable upon next restart or USB Flash
drive connection (with config.ini). Last set time would
be stored as a comment “;” in config.txt file.
23 ©
Electroware
2018