6.1.1 MiNiMUM eDge aND ceNteR DistaNces
Center to center E
min
= minimum distance between wire rope loops at the
same side of the joint.
Edge distance D
min
= the minimum distance of the wire rope loop to the
upper and lower edge of the concrete element.
Center to center C
max
= minimum distance between wire rope loops at
opposite sides of the joint.
Minimum width B
min
= minimum total wall width.
Wire rope loop
center to center
E
min
[mm]
edge distance
D
min
[mm]
center to center
C
max
[mm]
minimum width
B
min
[mm]
RVL 60-N
250
100
20
70
Resistances presented in tables 2…8 are calculated for static loads. RVL wire rope loops
are not designed to be used for lifting or as lifting loops.
Resistance of the RVL wire rope loop is defined by the weakest concrete in the joint
(element/joint concrete). The resistance calculations do not take into account cracks or
deformations in the joint. In resistance calculations it is assumed that the steel boxes
and the seam are fully filled with concrete.