Real Time Automation, Inc.
25
1-800-249-1612
Transmit Data
This side is configured to transmit data from the gateway into the ASCII device.
Use the following setup fields to help the 460 transmit an ASCII message.
1)
Enable
: Check this box to configure the Transmit Data section.
2)
Max Message Length
: Enter the max number of characters that can be transmitted by the gateway.
3)
Transmit Timeout:
Enter the amount of time (in ms) that the gateway waits before sending an ASCII
message (0 Sends Immediately). If the data has changed before the time expires, the gateway
immediately sends the message to the ASCII device.
4)
Delay Between Messages:
Enter the amount of time (in ms) that the gateway waits before verifying
a Change of State of the ASCII message OR will start the Transmit Timeout.
5)
Number of Start Delimiters:
Select the number of delimiters that will be added onto the beginning
of the ASCII string.
6)
Select Start Delimiters:
Select the start delimiters that should be added to the ASCII string.
7)
Number of End Delimiters:
Select the number of delimiters that will be added onto the end of the
ASCII string.
8)
Select End Delimiters:
Select the end delimiters that should be added to the ASCII string.
9)
ASCII Concatenating (Optional):
Additional concatenating can be performed on the string before
being written to the ASCII device. See the ASCII Configuration
–
ASCII Concatenating section for
more information.