SCREWS

 

 

Unscrew only two “

A

” screws to remove the case and 

therefore to set FC, CO and J3 jumpers. 

Fig. 6: 

For A-NDC 94, A-NDC 96 and A-NDC96.S models, remove the case to set FC and CO jumpers (see Fig. 6). 

CURRENT PROFILE MANAGEMENT (Dip 4 and Dip 5)

 

 

Dip 4 

Dip 5 

TYPE 

CHARACTERISTIC 

 

OFF 

OFF 

STANDARD 

 

OFF 

ON 

ENHANCED MOTOR SMOOTHNESS 

 

ON 

OFF 

ENHANCED MOTOR TORQUE 

 

ON 

ON 

MIXED (not recommended) 

Table 4 
 

APPLICATION NOTES: 

  A type ia a standard current profile (used in NDC series). 

  B  type  current  profile  performs  higher  motor  movement  smoothness  with  lower  acoustical  noise  and  vibrations. 

Smoothing effect of B type depends on resolution setting: the more resolution is low, the more smoothing is effective. 

  C type current profile performs higher motor torque. 

  D type current profile is not recommended. 

 

 

RESOLUTION

 

 

Dip 6 

Dip 7 

Dip 8 

STEPS FOR REV. 

 

ON 

ON 

ON 

12800 

 

ON 

ON 

OFF 

6400 

 

ON 

OFF 

ON 

6400 

 

ON 

OFF 

OFF 

6400 

 

OFF 

ON 

ON 

3200 

 

OFF 

ON 

OFF 

1600 

 

OFF 

OFF 

ON 

800 

 

OFF 

OFF 

OFF 

400 

Table 5 

5) 

DRIVE STATUS BY LED 

LED HV green:

 

ON

 

= supply voltage value in working range. 

 

OFF

  = no supply voltage or supply voltage out of working range 

 

LED FAU red:

 

ON

 

= drive set in no working state by one of the following protection: 

 

 

a

 – Thermal protection, if LED TER is ON   

 

 

 

b

 - Max or Min voltage when LED HV is OFF 

 

 

c

 - Short circuit or wrong connection at motor output when LED HV is ON 

 

OFF

  = drive active provided that LED HV is ON 

 

LED TER yellow:

 

ON

 

=   drive set in no working state by thermal protection. 

OFF 

=   drive active provided that LED HV is ON. 

 
 

Summary of Contents for A-NDC 04

Page 1: ...inimum and maximum value of nominal phase current setting 2 LOGIC INPUT AND OUTPUT SIGNALS connectors AM3 or C2 see Fig 1 7 9 and 10 All inputs and outputs are optically insulated mutually and respect...

Page 2: ...y common They can be used to connect the shield of logic signal cable if that is mandatory or useful depending on type of control system STEP DIRECTION and CURRENT OFF simplified input structure DRIVE...

Page 3: ...terminal B 16 Motor winding terminal A 17 Motor winding terminal A 18 Connection point for shield of motor shielded cable 4 MAIN SETTINGS Dip switches and jumpers Main setting must be done by the user...

Page 4: ...ations Smoothing effect of B type depends on resolution setting the more resolution is low the more smoothing is effective C type current profile performs higher motor torque D type current profile is...

Page 5: ...der to comply to directive 2004 108 CE and related standards EN 61800 3 installation has to be done according to schematics in Fig 7 and following indications Locate drives power supply transformer an...

Page 6: ...e right of the drive Do not obstruct air gratings The maximum surrounding air temperature must be lower than 40 C Maximum surrounding air temperature 40 C Installation is allowed in local environment...

Page 7: ...nsformer power 4 Fuse F2 type LP CC 8 by COOPER BUSSMAN LCC or equivalent Fuse F2 is mandatory for UL compliance 5 Rectifier bridge type according transformer power 6 Terminals 1 10 12 13 and 18 are i...

Page 8: ...ACKET sold separately L bracket suitable for vertical rail mounting of A NDC 04 A NDC 04 V A NDC 06 and A NDC 06 V KSM01 DIN A KIT BRACKET sold separately L bracket with plastic elements PHOENIX UM SE...

Page 9: ...from components side without heatsink Dimensions in millimeters CONNECTORS FOR A NDC 04 and A NDC 06 AM1 AMP MODU1 male 6 pole connector mod 280611 2 AM2 AMP MODU1 male 2 pole connector mod 280609 2 A...

Reviews: