42
Generally, maintaining as large as possible temperature differential between the
heating zone(s) and the spike zone, enables the furnace to generate the high
intensity spike. Dummy loading ahead of the systems being processed, to bring the
furnace to a stable condition, is most desirable and is also determined by trial and
error.
Atmosphere requirements are process dependent, and should be adjusted to provide
proper flow direction for volatile removal (if any), and for atmosphere composition
to control any adverse effects of atmosphere on the product at temperature.