Inst ruct ion and operat ing manual GHH
CS750 direct driven
(for-030/031013)
We recommend use of GHH RAND' s fully synthetic
high performance lubricant Silol. If you use exclusively
Silol or Silol FG (foodgrade) the interval for an oil
change doubles to 12 months. The period of the
manufacturer' s w arranty is extended for new screw
compressors
to
2
years,
for
remanufactured
compressors to 1 year. Depending on the operating
conditions, branded motor oils w ith API classification
SJ/CF as per SAE J183 can also be used. The
respective viscosity class (SAE class) can be taken
from the follow ing diagram.
Image 1.3.3
1.4
Oil cooler
A GHH CS750 is equipped w ith an integrated oil-cooler. If this oil-cooler is removed to
save space, the installation is equipped w ith an external oil-cooler.
An external oil-cooler is equipped w ith a 24 volt fan. The fan must be rotating during
operation and therefor the functioning of the fan must be checked during operation.
It is very important to keep the oil-cooler clean to prevent overheating of the compressor.
Observe the safety very carefully, the enclosure must be removed and rotating parts will
be accessible.
Image 1.4.1 Fan
Image 1.5.1
Oil cooler (art.no. 1342)
Ø 190mm 24 volt (art.no. 899)