RK2 Universal System Controller
20
MOUNTING OPTIONS
The RK2 has integrated mounting wings for retrofit installation in
new or existing construction. Additionally, the RK2 can be
directly attached to certain walls (wood, etc.) using screws.
An optional drywall rough-in bracket (RTI part #: 40-210306-16) is
available for conveniently locating the RK2 in new construction
installations.
WIRING CONNECTION OPTIONS
The RK2 can be wired either from the Control Port or the
Removable Terminal Block. A minimum of 3-conductor wire is
required for basic operation (+16VDC, GND, and IR DATA).
CAT5 cable can be used to power the RK2 up to 1000 feet (300m) if
a full wire pair is used for both +16VDC and GND. For longer
distances use the following size of unshielded multi-conductor
cable:
Wire Size
Distance
20 AWG
1300’ (400m)
18 AWG
2000’ (600m)