background image

 

 

 

 

INSTRUCTION AND 
OPERATING MANUAL  

 
 
 
Compressor installation SKL1200 
direct driven 

 

 

 

 

 

 

 
 
 

 

 

            

 

 

  

   

 

 

 

 

              

Summary of Contents for SKL1200

Page 1: ...INSTRUCTION AND OPERATING MANUAL Compressor installation SKL1200 direct driven...

Page 2: ...544 377050 The manual provides information about the following installation CVS SKL1200 direct DRIVEN Carefully read these instructions and the compressor instruction before setting up and going into...

Page 3: ...on and training personnel 6 2 3 Operating safety conscious 6 2 4 Safety instructions operator 6 2 5 Modifications and repairing spare parts 6 2 6 Modifications installation 6 3 Mounting installation 7...

Page 4: ...the PO number when contacting us by phone or mail You will find the PO number on the type plate of the installation Telephone number 0031 544 377050 Fax 0031 544 376499 Email info rti nl 1 2 Service...

Page 5: ...31013 1 4 Oil cooler A CVS SKL1200 is equipped with an oil cooler It is very important to keep the oil cooler clean to prevent overheating of the compressor Observe the safety very carefully the enclo...

Page 6: ...nts The latest edition of each of these regulations shall be applicable Any special official codes and regulations particularly safety regulations applicable to your operation in view of the local con...

Page 7: ...the PTO shaft Make sure the installation doesn t exceed the width of the truck D Measure the brackets and try to use all the holes in the chassis Brackets should be painted or otherwise protected agai...

Page 8: ...ll also start to run and will ensure the supply of oil to lubricate the bearings and the gears The oil pressure shall not fall below 0 3 bar With cold oil it may occur that the required oil pressure i...

Page 9: ...le the air intake filter is soiled and poses a risk of overheating and damages C The safety valve must open at maximum air pressure This valve must NOT be used as blow off valve To prevent overheating...

Page 10: ...e lower edge of the threaded hole 2 ATTENTION When filling via the bore of the vent plug 4 the oil level changes only after a time delay due to the oil flowing in B Check the air intake filter at regu...

Page 11: ...prevent corrosion To carry out the following inspections it is necessary to start the installation without enclosure Please note the dangers that can occur as a result of access to hot parts as compre...

Page 12: ...hange the oil filter Please find the instructions to demount the oil filter in the manual provided with the installation C Demount the non return valve installed in the discharge silencer and check fo...

Page 13: ...Check the insulation material in the enclosure for damages cover back panel floor panel if necessary repair and finish with sealant O Check if the fan louvers are open O Check if the discharge silenc...