4/23
Проверил: Р.Ч./19.03.2015г
When working outdoors, be aware of the wind direction. Wind can carry the coating substance across
greater distances - thus causing damage. When working indoors, provide for adequate ventilation.
Do not let children handle the device.
Never open the device yourself in order to carry out repairs in the electrical system!
Do not lay the spray gun.
Residual risks
Even when the power tool is used as prescribed it is not possible to eliminate all residual risk factors. The
following hazards may arise in connection with the power tool’s construction and design:
1.
Damage to lungs if an effective dust mask is not worn.
2.
Damage to hearing if effective hearing protection is not worn.
3.
Damages to health resulting from vibration emission if the power tool is being used over longer period
of time or not adequately managed and properly maintained.
WARNING!
This power tool produces an electromagnetic field during operation. This field may under
some circumstances interfere with active or passive medical implants. To reduce the risk of serious or
fatal injury, we recommend persons with medical implants to consult their physician and the medical
implant manufacturer before operating this machine.
Intend use
Coating Materials Suitable for Use
Water- and solvent-based paints, finishes, primers, 2-component paints, clear finishes, automotive
finishes, staining sealers and wood sealer-preservatives.
Coating Materials Not Suitable for Use
Wall paints (emulsion paints) etc., alkali and acidic paints.
Technical Data
Max. viscosity
50 DIN-s
Rated voltage
220 -240V ~
Rated input power
600W
Double insulation
回
Container capacity
700mL
Sound pressure level L
PA
78dB(A)
K
PA
=3 dB(A)
Sound power level L
WA
91dB(A)
K
WA