12 Installation
RVON-16
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.291
Rev. 06
DIP Switch 7
Boot Download Enable
Closed: Runs the boot download
Open (Default): Runs the native flash program.
Description: Switches to the boot download flash program. This program is sent with the RVON-16
card in case the native flash program becomes corrupt.
DIP Switch 8
DEBUG ONLY!
Closed: Debug mode.
Open
(Default): Normal operation mode.
WARNING
: DIP Switch 8 must be left in the Open position. It is reserved for debugging and can
have unintended consequences.
DIP Switch 9
Serial Port Select A
Closed: Select RS-485 (for serial port 1)
Open (Default): Select RS-232 (for serial port 1)
Description: Selects either RS-485 or RS-232 operation on the debug/serial pass through port.
DIP Switch 10
Serial Port Select B
Closed: Select RS-485 (for serial port 2)
Open (Default): Select RS-232 (for serial port 2)
Description: Selects either RS-485 or RS-232 on the second debug/serial pass through port.
DIP Switches
11-15
Not Used.
Keep in Open position.
DIP Switch 16
Not Available
Closed: Not Connected
Open (Default): Not Connected
FIGURE 4.
RVON-16 Switch Panels
Summary of Contents for RVON-16
Page 1: ...F 01U 193 291 Rev 06 DECEMBER 2011 RVON 16 RTS Voice Over Network...
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 iv RVON 16...
Page 10: ...6 Introduction RVON 16 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06...
Page 42: ...38 RVON 16 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06...
Page 49: ...RVON 16 45 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 Notes...