14 Installation
RVON-16
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.291
Rev. 06
2.
Right click an RVON-16 card, and select
RVON Configuration
.
The RVON Configuration screen appears
.
3.
From the RVON drop down list, select the
slot
in which the RVON-16 card resides, if it is not already selected.
4.
In the IP Address field, enter the
IP Address
you have assigned to the RVON-16.
5.
In the Network Mask field, enter the
Network Mask
of the network to which the RVON-16 is connected.
6.
In the Default Gateway field, enter the
Default Gateway Address
, if applicable, of the network to which the RVON-
16 card is connected.
A Default Gateway is only required if the RVON-16 connections are between LANs
.
7.
In the Target IP Addr field, enter the
Target IP Address
of the device you want to connect to over Ethernet.
8.
From the First Serial Baud Rate drop down list, select the
baud rate
at which the data is transmitted for the first serial
port.
NOTE:
Configuration of the 2nd pass-through port via AZedit is not supported.
NOTE:
You must configure the channels settings on each end of a connection to ensure the same codec and packet
size are selected at each end. Remember, the RVON-16 card has more channels which can be configured.
9.
From the RVON Channel drop down list, select the
channel
you want to use to communicate to another device across
the network.
10.
In the Device IP Addr: field, enter the
IP Address
of the device to which you want to connect.
11.
From the Device Type drop down list, select the
type of device
to which the RVON-16 card is connecting.
12.
From the Device Channel drop down list, select the
channel
on the device to which the RVON-16 communicates.
13.
From the CODEC type drop down list, select the
CODEC type
you want to use for this channel.
14.
From the Packet Size drop down list, select the
size
of each audio packet.
NOTE:
A CODEC is an algorithm used to compress audio. There are 5 Codices supported by Telex: G.711
s law,
G.711A, G.729AB, G.723 (5.3k), and G.723 (6.3k). The type of CODEC dictates the quality of audio you
hear and the network bandwidth used. The packet size determines how much audio is carried across the
network in each transmitted packet. The CODEC type and packet size chosen requires different amounts of
bandwidth from the network see “Specifications” on page 4. As with the CODEC type, the packet size you
choose for the audio transfer affects the audio you hear and the bandwidth you use over the network. The
larger the audio packet you choose to use, the lower the bandwidth used. However, the larger packet sized
can result in a higher delay and longer gaps if the packet is lost. On the other hand, smaller packet sizes
result in larger bandwidth use, but lower delays and smaller gaps if the packet is lost. The Intercom System
Engineer and the Network Administrator may want to work together in choosing the CODEC type and
packet size suitable for the size of the network, so degradation of the network resources does not happen.
Summary of Contents for RVON-16
Page 1: ...F 01U 193 291 Rev 06 DECEMBER 2011 RVON 16 RTS Voice Over Network...
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 iv RVON 16...
Page 10: ...6 Introduction RVON 16 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06...
Page 42: ...38 RVON 16 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06...
Page 49: ...RVON 16 45 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 Notes...