Carefully unwrap your RUBILASER L2D2
and insert 3 alkaline batteries (1.5 V AA) in
the battery compartment.
Place your RUBILASER L2D2 on a rather
flat surface. Keep in mind that the product
self levels correctly within an inclination
range of ±5º. If the device falls within this
range, there will be no problems for usage,
otherwise, the unit will emit a beep sound
and the laser lines as well as the red indica-
tor LED will blink once per second. Remem-
ber that the unit will automatically shut off if
it remains out of the self-leveling range for
more than 3 minutes. To re-activate it, you
will need to place the button in the “OFF”
position and immediately thereafter move it
to the “ON” position. Likewise, the unit will
automatically shut off if it remains activated
for more than 60 minutes and there is no
movement or change in the work condi-
tions.
Activate the unit by placing the button in
the “ON” position as shown in the follow-
ing figure
By default, the horizontal laser line will be
projected as well as the upper and lower
laser pointers. If you press the line selector
once (“LINE” button), the horizontal laser
line will disappear and the vertical laser line
will be projected (the two laser pointers
will remain). If you press the line selector
again, the horizontal laser line will be pro-
jected (the vertical laser line and the two
pointers will remain).
Once the instrument has been activated, any
of the laser lines with which you attempt to
work may need a few seconds to stabilize
due to the movement of the pendulum.
Before beginning to work, it is best to con-
duct a calibration test. Said test shall be
carried out periodically, after abrupt tem-
perature changes or especially if the unit
has been bumped. (Please see “Calibration
Test”).
During work, and if you wish to move the
unit from one place to another, you can
move the on/off button to the “LOCK”
position. In this mode, the pendulum will
remain blocked which will protect it against
any possible bumps, and the laser lines and
pointers will remain activated with a relative
inclination. The green LED will blink once
per second. It is worthy to note that in this
work mode, it will not be possible to select
the type of line that you wish to project,
however this application can be useful if you
wish to set the two laser lines and later in-
cline the unit.
Your RUBILASER L2D2 is a unit which is
normally used indoors. Nevertheless, if you
press the “MODE” button, it will enter the
pulsating laser mode, which will enable the
unit to work with an outdoor laser detec-
tor.
While working, if the battery is dying on
your RUBILASER L2D2, the red LED indi-
cator will blink twice per second. Once this
happens, it can continue functioning for ap-
proximately one hour before it shuts com-
pletely off.
Once the work is finished, you should move
the on/off button on the unit to the “OFF”
position. In this mode, the pendulum will re-
main fully blocked and protected from pos-
sible damage due to bumps and vibrations
while being transported.
INSTRUCTIONS
FOR USE
1
2
3
4
6
7
8
9
10
5