background image

23

9:51

9:51

9:51

9:51

9:51

9:51

P15

     650 m³/h

P16

     650 m³/h

P17

     850 m³/h

P18

     850 m³/h

P19

    1200 m³/h

P28

    1200 m³/h

English

MIN.VENT

SUPPLY AIR

MIN.VENT

EXTRACT AIR

BASIC VENT

SUPPLY AIR

BASIC VENT

EXTRACT AIR

SHOCK VENT

SUPPLY AIR

SHOCK VENT

EXTRACT AIR

Continued on page  29!

P 19  Intermittent ventilation supply air / P 28  Intermittent ventilation extract air

The air handling unit runs on closing the external contact  to the motion sensor and in Level 3 at the 

volume flows set in P19 and P28.

P 15  Minimum ventilation supply air / P 16  Minimum ventilation extract air

The volumetric flow can also be adjusted to „MINIMUM VENTILATION“ (night setback). This param

-

eter is controlled using the timer switch or Level 1 and can be set across the entire air volume range.

P 17  Basic ventilation supply air / P 18  Basic ventilation extract air

The designed volume flow for the „BASIC VENTILATION“ is set in m³/h on the control unit and reg

-

ulated via the parameters P17 and P18 at Level 2 The required duct pressure for „BASIC VENTILA

-

TION“ can be set in Pa with the control unit. The duct pressure can be individually set for supply and 

extract air. P 14  External control

www.ruck.eu

Summary of Contents for ROTO K 1050 V WOJL

Page 1: ...0 FC RLI 1200 FC RLI 1600 FC RLI 2000 FC RLI 700 EC RLI 1200 EC RLI 1600 EC RLI 2000 EC ROTO KOMPAKT ROTO K 1050 V WOJL ROTO K 1700 V WOJL ROTO K 2800 V WOJL ROTO K 4200 V WOJL Assembly and Operating...

Page 2: ...g a certain condition or suitability for a cer tain application can be derived from our information The informa tion given does not release the user from the obligation of own judgment and verificatio...

Page 3: ...installation positions 12 6 2 Duct connections 12 6 3 Application limits 12 6 4 Medium connections Heating Coil 12 7 Electrical connection 13 7 1 Overcurrent protection 14 7 2 Description external in...

Page 4: ...el heat exchanger 38 10 3 2 Belt drive for rotating wheel 38 10 3 3 Air filter 39 10 3 4 Changing the battery 40 11 Modbus communication interface 41 11 1 Wiring diagram 41 11 2 Interface information...

Page 5: ...operating instructions when you pass the product on to third parties 1 1 Rules and regulations 1 2 Guarantee and liability Also observe the generally applicable legal or otherwise binding regulations...

Page 6: ...a 2 3 Personnel qualifications In this manual there are safety instructions before the steps whenever there is a danger of per sonal injury or damage to the equipment The measures described to avoid t...

Page 7: ...r removed Make sure that all electrical connections are either used or covered Commission the product only if it is installed completely The power switch must be always fully functional and easy acces...

Page 8: ...or moving parts Failure to observe the hazard may lead to serious injury Work may only be performed once the impeller has come to a complete halt Never clean the internal space with flowing water or...

Page 9: ...internal and external walls The hous ing is insulated with 40 mm mineral wool The unit can be operated at a constant volume Control using external sensors provides the appropriate ventilation Data in...

Page 10: ...Model ROTO K V Fig 2 Typ ROTO K V Legend 15 Heating coil Heater 16 Frost protection controller 17 Supply air temperature sensor 18 Controller board 19 Safety labels 20 Cover for terminal box 21 Termi...

Page 11: ...perating manual and the regulations and standards in force The following points should be noted and followed The foundation must be even and levelled It must not exhibit unevenness or a slope in any d...

Page 12: ...e the freezing point of the water The only advantage of the bypass circuit over the admixture circuit arises when the pipe lengths between three way ball valve and water heater are very long Because t...

Page 13: ...between the unit and the duct system Check all protective measures after the electrical connection work earthing resistance etc Connection compartment Connections on the unit The connection compartme...

Page 14: ...ing diagram An external voltage must never be applied to this connection The control system would be destroyed Any devices providing a potential free contact e g central building control system can be...

Page 15: ...contact is closed Electrical connec tion with Vmax 230 VAC and Imax 2 A There is no double insulation from the mains Is the set value reached or the supply air temperature sinks below 16 C the contac...

Page 16: ...from the electricity supply and make sure that it cannot be switched back on again Never reach into the impeller or other rotating or moving parts Failure to observe the hazard may lead to serious in...

Page 17: ...u points and make changes to your unit settings and values A Control unit B Display Operating display 1 ON OFF selection 2 Setpoint temperature 3 Fan steps 4 Settings 5 Display current time C Control...

Page 18: ...selection buttons and can increase or reduce the setpoint value at the control unit The setting range is limited by parameters P 1 and P 2 Change fan step Fan step 2 is preset at first commissioning...

Page 19: ...ws the selection menu By touching the desired icon you can change between the parameters you need By selecting OK you confirm the chosen language The display switches into operating display 9 5 1 Lang...

Page 20: ...ettings icon The selection menu will then appear on the display Temperatures Display of the currently prevailing air temperatures in the device ODA Outside air temperature SUP Supply air temperature E...

Page 21: ...cted The individual inputs can be queried with the selection tools and The selection is made from right to left Description 1 true 0 false Position Consequence Description 1 unimplemented UNUSED 2 uni...

Page 22: ...K S Variable control with constant volume operation When confirming constant air volume control the following parameters have to be adjusted checked P 14 without external sensor Constant air volume c...

Page 23: ...and P28 P 15 Minimum ventilation supply air P 16 Minimum ventilation extract air The volumetric flow can also be adjusted to MINIMUM VENTILATION night setback This param eter is controlled using the t...

Page 24: ...gs can be found in the measuring range of the used measuring transducer The measur ing range is already preset for devices with integrated CO2 sensor Example Measuring area sensor 0 5000 ppm P 23 0 P...

Page 25: ...ontrolled by external measuring transducer VOC Sensor type VOC P 23 and P 24 These settings can be found in the measuring range of the used measuring transducer The measur ing range is already preset...

Page 26: ...211 0 Fax 49 7930 9211 150 SENSORTYPE W O EXT SENSOR Factory setting SENSORTYPE W O EXT SENSOR SENSORTYPE SENSORTYPE EXT CTRL SENSORTYPE SENSORTYPE EXT CTRL Continued on page 29 P 14 External control...

Page 27: ...s param eter is controlled using the timer switch and can be set across the entire allowed pressure range P 17 Basic ventilation supply air P 18 Basic ventilation extract air The required duct pressur...

Page 28: ...s The device automatically balances the air volume when sections will be added on or switched off The desired supply pressure must only be set on the control unit A response of the air volume controll...

Page 29: ...r compares the air temperature measured at the temperature sensors with the reference temperature set on the control unit In the case of heating a difference between the set point and actual temperatu...

Page 30: ...order to execute the filter calibration By touching the icon the unit switches to the calibration mode Display flashes CALIBRATE FILTER P 25 Supply air filter pressure loss Setting for pressure loss...

Page 31: ...operation The unit can only be switched on if the contact is closed If the contact is open the display will show NOT ENABLE The contact has to be closed and at the end confirmed by selecting OK The d...

Page 32: ...increases the control becomes more sensitive CAUTION Due to highly sensitive settings the control tends to pulsate P 6 Temperature correction The room temperature sensor within the control unit may sh...

Page 33: ...Setting the current time day You can switch from the Operating display to the Selection menu through the Settings icon Here you have the possibility to set the current time and weekday by pressing Se...

Page 34: ...the last item is confirmed for row 3 the display switched to day 2 Tuesday for which you can also set the ON and OFF switching times of the unit Days 3 to 7 then follow After you have set all the par...

Page 35: ...the hours and minutes is done the same way with and and with You may now set a second period of time for day 1 Monday in row 2 Proceed the same way as you did for row 1 If you do not wish to set a sec...

Page 36: ...3 0 00 0 00 English Tel 49 7930 9211 0 Fax 49 7930 9211 150 Basic ventilation Basic ventilation Basic ventilation Minimum ventilation Day 1 Day 1 Day 1 Fig 16 Systematic drawing without timer settings...

Page 37: ...chieved after 20 min an error message is displayed Afterwards the unit turns itself completely off until the fault is repaired see 14 2 Error table F07 9 10 2 Hot water coil The unit series can be equ...

Page 38: ...sion There must not be any faults or wear on the motor s pulley The pulley must be parallel to the circulating heating coil and must not twist 10 3 2 Belt drive for rotating wheel Rotating wheel heat...

Page 39: ...ensor this can be seen on the status display The filter must be changed when the level of clogging reaches 100 To reset the filter display after changing the filter press buttons A and at the same tim...

Page 40: ...y shows COMPLETED The contamination display is set back to 0 after calibration mode The filter change counter will then increase by one Calibrate filter Status display 10 3 4 Changing the battery Stat...

Page 41: ...ption 08 Hex Return Query Dat 00 Send the received message back 08 Hex Restart Communications 01 Restart communication 08 Hex Force Listen Only Mode 04 Switch to listen only mode Fig 25 Control unit 1...

Page 42: ...sic ventilation supply air See Table below or 50 500 Pa integer R W 40019 18 Basic ventilation extract air See Table below or 50 500 Pa integer R W 40020 19 Intermittent ventilation supply air See Tab...

Page 43: ...Reserved R W Bit 12 Reserved R W Bit 13 Reserved R W Bit 14 Reserved R W Bit 15 Reserved R W Register address Parameter name Value range ROTO K 1050 V ROTO K 1700 V ROTO K 2800 V ROTO K 4200 V ROTO K...

Page 44: ...er R 30007 6 Pressure difference filter 1 0 1000 Pa integer R 30008 7 Pressure difference filter 2 0 1000 Pa integer R 30009 8 Soiling indicator 1 0 100 integer R 30010 9 Soiling indicator 2 0 100 int...

Page 45: ...Damper position 7 Frost protection triggered 8 Safety thermostat triggered 9 Thermal switch for ventilator triggered 10 Error fan 11 Reserved 12 Not enabled 13 Cooling plant defective 14 Fire detector...

Page 46: ...1 Have the unit s operating conditions or operating range been changed 2 Have any changes e g reconfigurations or repairs been performed on the overall system installation electrics control or to the...

Page 47: ...xtracted air temperature sensor is defective or the cable is broken Replace the defective temperature sensor or replace the broken cable if necessary After the failure reason is remedied the failure m...

Page 48: ...ch the unit off check wiring and fans and if needed replace damaged fan After the failure reason is remedied the failure must be confirmed with OK Error in rotor motor Error message to the control of...

Page 49: ...th W mm 816 954 1153 1409 Height H mm 1099 1253 1610 1903 Nominal width NW mm 600 x 250 600 x 250 250 x 850 1100 x 350 Weight kg 146 248 362 552 Operating voltage V 400V 3 N 400V 3 N 400V 3 N 400V 3 N...

Page 50: ...component 5 20 10 P 6 Temp correction of the ambient temp sensor on the control unit 5 C 5 C 0 P 7 Address 1 247 1 P 8 Baud rate 2400 4800 9600 14400 19200 9600 P 9 Fan calibration supply air 800 1200...

Page 51: ...xtract Air Fortluft Exhaust Air Aussenluft Fresh Air 1150 998 1099 209 5 225 386 33 2x3 4 Innengewinde 816 500 523 220 197 72 197 72 197 72 53 2 16xM8 Einietmuter 1517 816 ROTO K 1050 V English 16 2 T...

Page 52: ...52 1399 1121 1150 143315 142269 669 315 819 8 English Tel 49 7930 9211 0 Fax 49 7930 9211 150 ROTO K 1050 V Transition 315...

Page 53: ...Air Abluft Extract Air Fortluft Exhaust Air Aussenluft Fresh Air 1375 1161 1253 291 5 33 492 222 3 2x3 4 Gewinde 1694 891 891 600 250 76 250 76 250 76 273 53 5 623 16 x M8 Einietmuter ROTO K 1700 V En...

Page 54: ...54 1595 1375 1553 1253 791 400 1378 143324 143321 140188 English Tel 49 7930 9211 0 Fax 49 7930 9211 150 ROTO K 1700 V Transition 400...

Page 55: ...5 557 8 221 4 2 x 3 4 Gewinde 45 6 250 850 1092 280 880 110 118 110 250 16 x M8 Einietmuter Abluft Extract Air Aussenluft Fresh Air Fortluft Exhaust Air Zuluft Supply Air 1092 1948 Offene T re ROTO K...

Page 56: ...56 1603 4 1812 1495 145539 145540 139032 English Tel 49 7930 9211 0 Fax 49 7930 9211 150 ROTO K 2800 V MAK Motor shut off flap...

Page 57: ...Abluft Extract Air Fortluft Exhaust Air Aussenluft Fresh Air 1800 1811 1903 518 223 659 33 2x3 4 Innengewinde 1355 5 2351 1355 5 1099 349 91 349 91 349 91 380 53 5 1130 16xM8 Einietmuter ROTO K 4200 V...

Page 58: ...58 1903 2112 1803 1360 145594 145596 141531 English Tel 49 7930 9211 0 Fax 49 7930 9211 150 ROTO K 4200 V MAK Motor shut off flap...

Page 59: ...1 L1 L1 L1 Einspeisung Power input 400V 3 N 50Hz Sicherung extern max 10A Fuse external max 10A Zuluftventilator 2 Supply air fan 2 Hauptschalter Main switch bk ye bk ye B1 Volumenstrom Zuluft Supply...

Page 60: ...L1 L1 Einspeisung Power input 400V 3 N 50Hz Sicherung extern max 10A Fuse external max 10A Abluftventilator 2 Extract air fan 2 Hauptschalter Main switch bk ye bk ye B1 Volumenstrom Zuluft Supply air...

Page 61: ...00V 3 N 50Hz Sicherung extern max 16A Fuse external max 16A Zuluftventilator Supply air fan Hauptschalter Main switch wh bu ye bu ye wh St rung Fault St rung Fault wh wh B1 Volumenstrom Zuluft Supply...

Page 62: ...n max 16A Fuse external max 16A Zuluftventilator Supply air fan Abluftventilator Extract air fan Hauptschalter Main switch wh bu ye bu ye wh St rung Fault St rung Fault wh wh B1 Volumenstrom Zuluft Su...

Page 63: ...icherung extern max 16A Fuse external max 16A Zuluftventilator Supply air fan Abluftventilator Extract air fan Hauptschalter Main switch wh bu ye bu ye wh St rung Fault St rung Fault wh wh B1 Volumens...

Page 64: ...A Out 0V 0V 24V D In A Out A Out 24V D In 24V 24V 24V 24V 24V 24V 24V D In D In D In D In D In D In Temp 1 Temp 2 Temp 3 Temp 4 L1 L1 L1 L1 B1 Volumenstrom Zuluft Supply air flow B2 Volumenstrom Abluf...

Page 65: ...nluft Fresh air Abluft Extract air Zuluft Supply air Bedienger t Remote control Optional manuelle Verbindung mit einem Kabel manuell connection with a cable 120Ohm 3 Wege Ventil 3 way valve K hlen Opt...

Page 66: ...A B 24V 1 X14 2 3 4 5 6 7 8 9 10 11 12 13 1 X9 2 3 4 5 6 7 8 9 N X3 2 3 N 5 6 N 8 9 1 X6 2 3 N 5 6 N 8 9 1 X16 2 N 4 5 6 7 8 9 N X4 N N 4 5 6 7 8 9 L1 L11L2 L21L3 L31 N N N PE PE PE PE 15 30 V 0V 0 10...

Page 67: ...XB1 XB3 F1 F2 0V 0V 0V 0V 0V L1 L1 L1 L1 L1 L1 L1 L1 A In A In A In A Out A Out 0V 0V 24V D In A Out A Out 24V D In 24V 24V 24V 24V 24V 24V 24V D In D In D In D In D In D In Temp 1 Temp 2 Temp 3 Temp...

Page 68: ...ents concerning a certain condition or suitability for a certain application can be derived from our information The information given does not release the user from the obligation of own judgment and...

Reviews: