9.3. Display user level
You move to the user level by pushing and holding the ON/OFF button for approx. 4 seconds.
The display then changes to the volumetric flow. The individual menu points can be called up with
buttons A (▲ and ▼) on the control unit. Press the „Mode button“ (M) once to go back to the start
functions and the status display.
Control unit outputs
Display of the assigned outputs on the control
unit.
The individual outputs can be interrogated
with buttons B (▲ and ▼).
The selection is made from right to left.
Description:
0 = no relay connected
1 = relay connected
Position: Consequence: Description:
1
unimplemented
UNUSED
2
unimplemented
UNUSED
3
1 = on
ENABLE COLDNESS
4
1 = opening
BYPASS OPEN
5
1 = closing
BYPASS CLOSE
6
1 = opening
HEAT.VALVE OPEN
7
1 = closing
HEAT.VALVE CLOSE
8
1 = on
CIRCULATOR PUMP
9
1 = error
FAULT RELAIS
10
1 = closing
AIR FLAP CLOSE
11
1 = opening
AIR FLAP OPEN
12
1 = opening
COOL.VALVE OPEN
13
1 = closing
COOL.VALVE CLOSE
14
1 = on
HEATING
15
1 = on
ENABLE FRQ CONVERTER
16
unimplemented
UNUSED
Temperatures
Display of the currently prevailing air temperatures in the device.
i
» Outside air - temperature
IN
» Supply air - temperature
h
» Extract air - temperature
OUT
» Exhaust air - temperature
Room temperature
This shows the value of the current room temperature, measured by a temperature sensor in the
control unit.
The value after V shows the software version of your unit.
Pressure loss at the filter
Display for the current pressure loss at the filters.
Control unit inputs
Display of the assigned inputs on the control
unit.
The individual inputs can be interrogated with
buttons B (▲ and ▼).
The selection is made from right to left.
Description:
0 = false
1 = true
Position: Consequence: Description:
1
UNIT ENABLE
2
1 = OK
FRQ. CONVERT.FAULT
3
1 = OK
MOTOR PROTECTION
4
1 = OK
FROST PROTECTION
5
MOTION DETECTOR
6
1 = OK
FIRE PROTECTION
7
unimplemented
UNUSED
8
unimplemented
UNUSED
9
unimplemented
UNUSED
10
unimplemented
UNUSED
11
unimplemented
UNUSED
12
unimplemented
UNUSED
13
unimplemented
UNUSED
14
unimplemented
UNUSED
15
unimplemented
UNUSED
16
unimplemented
UNUSED
Actual value volumetric flow
Display of the actual running volumetric flow.
i
Volumetric flow outside air - supply air
h
Volumetric flow extract air - exhaust air
Constant 4 sec
hold down
ROOM TEMPERATURE
21,0° V 3.0
SUPPLY AIR 88PA
EXTRACT AIR92PA
UNUSED
h
0011001011001111
UNIT UNABLE
i
0000000000001111