background image

 

17 

Chapter 4 INSTALLAION

Глава 4 УСТАНОВКА

Connection of photocell (Picture 17):

 The wires are 

labeled No. 200#, 201# and 203#, to connect the 
brown wire to No. 201#, black wire to No. 203# in the 
terminal, ant the blue wire to No. 200#. 

Подключение фотодатчика (Рис. 17):

 Провода 

имеющие нумерацию №№ 200, 201, 203 подключать: 
коричневый к № 201, чёрный к клемме № 203, и 
голубой к № 200. 

 

Picture / Рисунок 18

 (Photocell / Фотодатчик) 

 

HYDRAULIC PIPELINE CONNECTION: 

МОНТАЖ ГИДРАВЛИЧЕСКОГО КОНТУРА 

 

Follow “oil pipe connection diagram“ to 
connect the oil pipes. 
Only skilled and authorized person is  
allowed to perform the operations. And pay 

particularly attention to the protection of oil pipe 
fitting 

Осуществляйте монтаж гидравлического контура 
в соответствии с гидравлической схемой. 
Только опытный и уполномоченный персонал 
может выполнять данные операции. Особое 
внимание следует уделить защите шланговых 
фиттингов от попадания инородных частиц. 

-Following oil pipe number to lead the oil pipe out from  
two oil make-up stop valve “H” and “I” of control box and 
then connect them to the cylinder. (Refer to “oil pipe 
diagram”) 

- Соблюдая нумерацию гидравлических шлангов 
проложите их от запорных клапанов «H» и «I» стойки 
управления и соедините их с гидроцилиндрами 
(следуя гидравлической схеме) 

- When connect the oil pipes, be careful not to mistake 
each oil pipe number. 

- При подключении гидравлических шлангов 
соблюдайте их нумерацию. 

- During the standard installation, control box is in the 
nearside of vehicle-entering direction. If placed on the  
right should adjust relevant oil pipe. 

- В стандартной комплектации стойка управления 
располагается слева по направлению движения 
автомобиля. Если требуется разместить стойку с 
права по ходу движения, то необходимо удлиннить 
гидравлические шланги. 
 

COMPRESSED AIR PIPE CONNECTION: 

ПОДКЛЮЧЕНИЕ ПНЕВМОПИТАНИЯ: 

 

Follow “air loop diagram“ to connect air 
loop. Only skilled and authorized person is 
allowed to perform the operations. 

Подключайте пневмопитание в соответствии с 
пневматической схемой. Только опытный и 
уполномоченный персонал может выполнять 
данные операции. 

- Connect Ø8×6 compressed air supply pipe to the air 
supply jaws of solenoid air valve inside the control box. 
(Picture19) 

- Подключите пневмошланг Ø8×6 к воздушному 
фиттингу э/м клапана внутри стойки управления 
(Рисунок19) 

- Follow “air loop diagram “to lead the compressed air  
pipe out from solenoid air valve and then connect it to the 
lock latch air cylinder. (Picture 20) 

- Следуя пневматической схеме присоедините 
пневмошланг от э/м клапана к пневмоцилиндру 
зубчатого фиксатора. (Рис. 20) 

- Pay attention to the protection of windpipe tie-in to 
prevent impurities from entering compressed air circuit. 

- Исключите попадание инородных частиц / 
элементов внутрь пневматических шлангов. 

- Connect compressed air pipe to the extra-installed 
grease separator which is in front of control box to   
prolong the lift of pneumatic components and the  
reliability of action. 

- Включите в пневмолинию масляный сепаратор для 
продления срока службы компонентов пневмолинии. 

- In the process of windpipe installation, the windpipe can 
not be folded or tied to avoid that the air loop is not  
smooth or it is jammed. 

- В процессе прокладки пневмошлангов, их не 
следует перегибать (пережимать) во избежание 
повреждений. 

- Before leading the compressed air supply pipe to the air 
supply lock latch of solenoid air valve inside the control 
box, should extra install grease separator to separate 
compressed air, avoiding the failure of pneumatic cell 
action. 

- Перед подводом сжатого воздуха к воздушному 
клапану зубчатого фиксатора, установите масляный 
сепаратор для обеспечения благоприятного режима 
работы данного фиксатора. 

Summary of Contents for RLSS-301

Page 1: ...Small scissor lift RLSS 301 3 0T RLSS 301 3 0 USER S MANUAL Operating Manual Instructions Ref B3 GC 3 0SS user s manual 20090821 19 2012 Serial No Year of Manufacture...

Page 2: ...peaking users However if you have any questions remarks or notes caused by this manual please contact our specialists immediately RUDETRANSSERVICE Ltd Russia 173003 Velikiy Novgorod B Saint Petersburg...

Page 3: ...y 3 11 Chapter 4 Installation 4 15 Chapter 5 Adjustment 5 18 Chapter 6 Operation 6 21 Chapter 7 Maintenance and care 7 22 Chapter 7 Failure and resolutions 8 23 Chapter 9 Appendix 9 26 9 1 Hydraulic s...

Page 4: ...hat all items specified in the delivery notes are included In case of missing parts possible defects or damage due to transport the person in charge or the carrier must be immediately informed Further...

Page 5: ...ized personnel from the licensed dealer or an service center authorized by the manufacturer The manufacturer declines all responsibility for injury to persons or damage to vehicles or objects when any...

Page 6: ...t for hydraulic failure and over loading So when the oil pipe bursts the machine will not fall quickly Use high quality hydraulic or electric element parts made in Italy Germany Japan and so on Own ma...

Page 7: ...lift weight kg 3000 3 Main machine Lift height mm 960 4 Platform initial height mm 105 5 Platform length mm 1450 6 Platform width mm 530 7 Lifting time s 50 8 Descent time s 60 9 Overall length mm 204...

Page 8: ...0 5A 220 10A Max Frequency Hz 50 Poles 4 Speed 1450 Building shape B14 Insulation class F When connecting the motor refer to the enclosed diagrams and the motor direction is clockwise PUMP Type P4 3 M...

Page 9: ...Clean the basic layer thickness of concrete 150mm the leveling of whole length 10mm 150 10 Remarks 1 Fix ground bolts before loading 1 2 The control box can be placed on the left or right side 2 Pict...

Page 10: ...ifting weight is 3000Kg 3000 THE MAX DIMENSION OF VEHICLE The following diagrams illustrate criteria used to define the operating limits of the lift The lower parts of the vehicle underbody could inte...

Page 11: ...s for personnel or lifting personnel Use as a press for crushing purposes Use as elevator Use as a lift jack for lifting vehicle bodies or changing wheels The manufacturer is not liable for any injury...

Page 12: ...to persons and or damage the lift the vehicle or other property RISK OF ELECTRIC SHOCK a specific safety notice placed on the lift in areas where the risk of electric shock is particularly high Risk...

Page 13: ...0 Picture 9 Picture 10 There is nothing abnormal should be left on the safety modules to prevent safety gear from occlude normally RISKS FOR PERSONNEL This heading illustrates potential risks for the...

Page 14: ...t and also the platforms must be kept clean Remove any oil spills immediately 12 Picture 11 Risk of impact Picture 12 Risk of slippine RISK OF ELECTRIC SHOCK Risk of electric shock that in area of the...

Page 15: ...st be 1000 mm at least taking into consideration the necessary space to work easily Because space for the control site and for possible runways in case of emergency is also necessary The 1000 The room...

Page 16: ...TION Connect the electrical and oil line according to the electric wiring diagram and oil line connection Only after connecting the hydraulic system can connect the air loop can not damage oil pipe wi...

Page 17: ...ipe COMPRESSED AIR PIPE CONNECTION Follow air loop diagram to connect air loop Only skilled and authorized person is allowed to perform the operations Connect 8 6 compressed air supply pipe to the air...

Page 18: ...kwise looking downward if not turn off the power then change the phase of the motor UP When turn on power there is high voltage in the control box only authorized person can operate it Turn on the air...

Page 19: ...ill affect the quality of solidity Adjust the parallel of the platform and the distance of two platforms as Picture 4 requires 4 Fix the anchor bolts with a percussion electric drill percussion drill...

Page 20: ...acles do the test again SB0 Load of machine test Drive the vehicle whose weight doesn t exceed maximum lifting weight to the platforms and then the driver leaves it Put the lift rubber cushion on the...

Page 21: ...machine should be lowered to the lowest position on ground and remove vehicle and cut off power supply Instructions on electric operation see the operation panel Picture 24 LIFTING Press UP button the...

Page 22: ...MERGENCY MANUAL OPERATION FOR LOWERING POWER FAILURE When lowering through manual operation should observe the condition of platform at any time because there are vehicles on the platform If there is...

Page 23: ...ates when forcing the contactor down with an isolation rod check the control circuit If the voltage at two ends of the contactor coil is normal replace the contactor 2 The motor does not run in liftin...

Page 24: ...coil of the lowering solenoid valve and check the right turn tightness of its end copper nut and so on 4 When press Lower button the machine is not lowered 5 The antiknock valve is blocked Remove the...

Page 25: ...e right and left platforms are not synchrono us and not in the same height 3 The oil make up stop valve can not be closed tightly and almost make up oil and adjust every day Replace oil make up stop v...

Page 26: ...raulic schematic drawing 9 1 1 3 sub cylinder 1 3 9 gear pump 9 2 4 main cylinder 2 4 10 flow control valve 10 5 stop valve 5 11 pump motor 11 6 check valve 6 12 filter 12 7 overflow valve 7 13 oil ta...

Page 27: ...27 9 APPENDIX 9 9 2 Oil pipe connection diagram 9 2...

Page 28: ...28 28 9 APPENDIX 9 9 3 Circuit diagram 220V 9 3 220...

Page 29: ...29 9 APPENDIX 9 9 4 Wiring diagram 220V 9 4 220...

Page 30: ...30 9 APPENDIX 9 9 5 Circuit diagram 380V 9 5 380...

Page 31: ...31 9 APPENDIX 9 9 6 Wiring diagram 380V 9 6 380...

Reviews: