To open the shaft push the handle about 1 cm away from you to release the locking mechanism.
then pull the handle towards you until the limit stop is reached. Now let go off the handle so that
the slider can lock itself in this position through its own weight. After filling, ideally with 110% of the
shaft volume, locking and pre-compacting is started. Always keep both hands on the handle until
the shaft is locked. Lift the handle a few millimeters out of its locked position and then push the
slider down until the shaft is completely closed. This process is finished when the bottom part of the
slider lies against the machine and when the machine starts working automatically with a started
process program.
3.8. Product discharge
The product discharge for SR 1 and SR 1 turbo is always composed of cutting area door and
discharge funnel.
3.8.1 The use of boxes
The machine has a discharge height of 450 mm.
this makes it possible to use boxes of up to
300 mm height on top of a trolley.
Therefore there is the choice to use euro standard
boxes of the sizes E 1, E 2 and E 3 respectively.
The discharge funnel inside the cutting area door
Avoids Product from falling passed the boxes.
The funnel is inserted by holding it at an angle
followed by lowering it in a horizontal position
on to the holders at the bottom of the cutting
area door.