If the limit switch output high level signal when the home switch is triggered, you should select “Hight”.
If the limit switch output low level signal when the home switch is triggered, you should select “Low”.
NOTICE: the limit
switch must be according with the limit polar parameter. Or the motion
control will be prohibited.
4)
Control signal
:
Pulse+dir signal is valid to motor control.
5)
pulse equivalency
:
That means the quality of the pulse when axis move 1
millimeter.
6)
Cut range
:
Set the cut range according to the machine work area. The cut range is usually smaller than the machine
work area.
7)
Maximum velocity.
The limit of the work velocity according to the machine and motor ability.
8)
Start velocity
:
The first start velocity according to the motor’s
performance
。
9)
Maximum
acceleration
:
The maximum
acceleration is to limit the cut velocity and the jump velocity.
10)
Jog acceleration
。
11)
Emergency Stop
acceleration
The acceleration is for the emergency stop, such as limit trigger, alarm trigger.
12)
Write para
Save the parameters to the card.
13)
Read para
Read the parameters from the card.
14)
Open
Open the file of .RDSet format,to set the parameters.
2 System parameter
:
System parameter is relation with the Lasercuttist configuration.