Picture3-18 Machine Parameters
Motion direction polarity
When you open the “Test---machine Test”, you can run a motion test. If you send positive
pulses to the motor, the direction of the axis moving is
opposite to the machine positive
direction that has been decided by the home switch. You should change the polarity of the
direction polarity. The default is positive.
Home switch Polarity
Home switch is for the machine going home. If the motion axis has met the home switch,
the home switch is triggered. There are two statuses when the home switch triggered. One is
low level and the other is high level.
If the home polarity is set to be negative, that means lasercuttist will consider the valid
level is low. If the home polarity is set to be positive, that means lasercuttist will consider the
valid level is high.
For example, the home switch is normal open. One terminal of the home switch is
connected to OGND and the other terminal is connect to the control board home input. The
home polarity must be set negative. That means the valid level is low level. If the home switch
is normal close, The home polarity must be set positive. That means the valid level is high
level.
Limit switch polarity
Limit switch polarity configuration is
similar to home switch polarity configuration.