LaserCuttistV1.2 Laser Cutting system
RuiDa Technology E-Mail:
support@rd-acs.com
1TH FLOOR,5TH BUILDING,NANYOU
TIANAN INDUSTRIAL ZONE,SHENZHEN
Web:
www.rd-acs.com
Phone: (086)0755-26066687
FAX: 0755-2698287
63
Control mode
The motor control output is pulse + dir.
Pulse equivalency
Pulse equivalency is the
conversion relation of the rotate pulse and the axis line movement.
Pulse equivalency is very important and should be set correctly.
You can follow the steps to set up the pulse equivalency.
(1)
Firstly you should calculate the pulse equivalency according to the
pitch of screw
and pulses when motor turning one circle.
(2)
Then write the theoretical
pulse equivalency to machine parameters.
The
theoretical
pulse equivalency must have some error with the actual pulse
equivalency. So the value must be revised.
(3)
Running X axis for a 200mm movement, marked on the start point and the end point.
Measure the distance between the start point and the end point. Then write the
200mm and the actual distance to the dialog. As is shown in picture 3-19.
(4)
Click ok, the pulse equivalency will be calculated automatically. The same steps to
the Y axis.
Picture 3-19 pulse equivalency calculate
Cut Range
Cut range should be set for the soft limit. Another purpose is to make the cut window displayed
in the lasercuttist similar with the machine cut platform.
Maximum velocity