background image

3

Thank you very much for purchasing the wind turbine Black 600. You have bought a 
premium product which silhouettes explicitly against products of our competitors. The wind 
turbines of the Black series have no magnetic detent torque and holding torque, which allows 
a start-up from wind speeds of 0,8 m/sec. From 1, 8 m/sec on, you are able to be in loading 
area. The wires inside the mast will not roll up, because yaw control is made via abrasive ring 
contacts. 
 
In order to get a bigger turbine’s lifespan, there are some necessary advices for mounting the 
wind turbine assuredly and reliably. 
Please notice that this manual is a part of the product and has to be followed strictly, so please 
read this manual carefully before installing the wind turbine. This manual should be 
positioned near the product and it should be given to possible new owners. 
 
This manual describes the function, installation, operating and attendance of the wind turbine. 
 
It addresses itself to the raiser of the turbine who should be technically experienced. If this is 
not the case, please let the installation be made by a technician.  
 
The wind turbines BLACK are available in 12 or 24 Volt for charging batteries and in 48 Volt 
for supplying feed-in converters. There will also be a 500 Watt version in the near future. 

 

 
Wind turbines for battery charging which are connected to a solar panel, are appropriate to the 
following appliances: street lamps, supply of gauging stations, traffic management systems, 
emergency call systems, isolated systems like summer residences, garden plot, camping, 
advertisement, lighting of billboards, for primary health care in developing countries, 
Wireless Lan Access Point and everywhere, where there is no electrical connection. There is 
also available a feed-in converter for the wind turbine BLACK which are able to feed in the 
electricity network.  
These information are dependable, but the manufacturer does not take responsibility for 
impreciseness or omissions. The user of this information and of this product takes the full risk 
and responsibility. All specifications are changeable without any other messages. Wind 
turbines have to correspond to the local and national appointments, norms and laws, like other 
electric devices and sources, too. In some regions, you also need a building license before 
installation of the wind turbine. Before you start to mount the turbine, please check if you are 
allowed to install a turbine at your location. 
 
 
 

Summary of Contents for Black 600

Page 1: ...1 Assembly instructions and manual for the wind turbine Black 600...

Page 2: ...ecurity advices 3 technical specifications of the wind turbine 4 assembly of the wind turbine 5 connection to the charge controller 6 connection to the feed in inverter 7 troubleshooting 8 checkup and...

Page 3: ...nes BLACK are available in 12 or 24 Volt for charging batteries and in 48 Volt for supplying feed in converters There will also be a 500 Watt version in the near future Wind turbines for battery charg...

Page 4: ...than 100 times per minute or a rotor blade is tied to the tower so that you cannot get hurt by the rotating rotor The tower and the mounting to the tower have to resist the forces that are created by...

Page 5: ...it can happen that a wind turbine was not assembled completely or that a screw disengaged itself during transportation Please check all single assemblies concerning damages and unfixed assemblies e g...

Page 6: ...4 Nylon washer 1 5 Generator holder 1 6 Generator 1 7 Blades made from carbone nylon 3 8 Aluminium plate 1 9 M8 washer 9 10 M8 spring washer 9 11 M 8 x 45 screw 9 12 Cover 1 13 M 8 x 45 screw 1 14 Po...

Page 7: ...1 3 16 5 11 815 2 19 4201 1 4 39 2 12 1058 4 20 4900 0 5 76 5 13 1345 7 21 5672 4 6 132 3 14 1680 7 22 6521 9 7 210 1 15 2067 2 23 7452 3 for an air density of 1 225 kg m which corresponds dry air at...

Page 8: ...e houses hedges trees hills etc The bigger the rotor diameter the more constantly the rotor has to be blown You can choose the perfect installation location the most easily when you take a long stake...

Page 9: ...placed with three others otherwise the generator can be out of balance Please mount the rotor blades in a wind free location the rotundity of the blade has to point to the generator and the even side...

Page 10: ...also to protect the Black 600 of overload The tail turns slowly out of the wind when the wind speed is too high at about 550 Watt Therefore it is important that the tail is mounted correctly The tail...

Page 11: ...e triple core cable to the top of the tower Because the cable has got a heavy empty weight we suggest to mount the cable inside the tower with an extra strain relief before you connect the cable to th...

Page 12: ...wer Notice that the screws may not go deeper than 11 mm into the tower pressure because the cables lie in the middle of the axle Erect the tower vertically A slant tower stresses the wind turbine s me...

Page 13: ...the middle position tell you if the charge controller has found a 12 or 24 volts system The very right LED tells you if the brake is activated at the moment activation can be made manually or automati...

Page 14: ...he battery will not be charged correctly To put things right you can switch on a small device during charging which reduces the voltage and avoids braking The brake of the charge controller is control...

Page 15: ...olts Charge shows you how much ampere hours were charged into the battery This value is used as a relation value because every 10 seconds information of the charge controller get requested It is the s...

Page 16: ...nnect bigger batteries This function can also be used in order to define the engine speed How to calculate the correct value capacity of the wind turbine divided by the end charging voltage which mean...

Page 17: ...is not enough wind The wind turbine or the charge controller is defect In order to find the mistake we will have to do a process of elimination Therefore you should disconnect the three cores of the w...

Page 18: ...ositioned vertically and if all wiring is tight Does the wind turbine turn easily into the wind Are the rotor blades still balanced well When there is a damage at the blades the wind turbine has to be...

Page 19: ...r Zhejiang Ruihua decides whether a wind turbine has to be repaired or replaced by a new one Apart from that the general terms and conditions of Zhejiang Ruihua are valid The company Zhejiang Ruihua M...

Reviews: